User's Manual

G3S-800-180-029 Installation & Service Manual
Copyright Powerwave Technologies, Inc., April 2002. All rights reserved
044-05112 Rev. A 5-4 April 2002
5-5.1.4 Spurious Test
8. With the power amplifier set at 180 watts power output, use the spectrum analyzer and check
the frequency band from 869 MHz to 894 MHz for spurious signals. Spurious signals should
be -60 dBc maximum. Record test data in table 5-3.
5-5.1.5 Input Return Loss Test
9. Reset and turn on amplifier module. Read and record the S
11
return loss measurement on
network analyzer. Input return loss should be –16 dB maximum. Record test data in table
5-3.
Table 5-3 Multicarrier Cellular Amplifier Test Data Sheet
DATE _________________________________
AMPLIFIER S/N _________________________
TEST CONDITIONS:
Load and Source Impedance: 50 Ohms
VSWR: < 1.2:1
Supply Voltage: +27 Vdc ±1.0 Vdc
TEST SPECIFICATION MIN MAX DATA
4-TONE IMD
Vcc = 27 Vdc
PO = 180 W
Freq.: 880, 883, 886, and 889
MHz
-60 dBc
RF Gain
Vcc = 27 Vdc
PO = 180 W
Freq. = 880 MHz
57.5 dB 58.5 dB
Gain Flatness
Vcc = 27 Vdc ±1 Vdc
PO =180 W
869-894 MHz Band
-0.5 dB +0.5 dB
Harmonics
Vcc = 27 Vdc
PO = 180 W
869-894 MHz Band
5 dBm
Spurious
Vcc = 27 Vdc
PO =180 W
869-894 MHz Band
-60 dBc
Input Return
Loss
Vcc = 27 Vdc
PO = 180 W
869-894 MHz Band
-16 dB
DC Power
Vcc = 27 Vdc
PO = 180 W
4 Tones
70 Amps
PASS _________________________________ FAIL _______________________________
Tested by ______________________________