User's Manual

Table Of Contents
G3S-800-140 Installation & Service Manual
044-05095 Rev. A 5-4 February 2001
5-5.5 Spurious Test
8. With the power amplifier set at 140 watts power output, use the spectrum analyzer and check
the frequency band from 869 MHz to 894 MHz for spurious signals. Spurious signals should
be -60 dBc maximum. Record test data in table 5-3.
5-5.6 Input Return Loss Test
9. Reset and turn on amplifier module. Read and record the S
11
return loss measurement on
network analyzer. Input return loss should be –16 dB maximum. Record test data in table
5-3.