Standby (Offline) UPS PowerWalker VFD 600 APFC PowerWalker VFD 800 APFC PowerWalker VFD 600 APFC/FR PowerWalker VFD 800 APFC/FR Manual (EN) Uninterruptible Power Supply System
IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS SAVE THESE CAUTION!! Please read the following information carefully and save this manual for further reference. Disregard of these safety notes may endanger life or health, as well as the function of the equipment and the safety of your data. Risk of Electric Shock Heatsinks are live. Disconnect unit before servicing. Risk of Electric Shock. This unit receives power from more than one source.
batteries terminal. To replace the batteries by qualified service personnel. Use the same number and type of sealed lead-acid batteries. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible. Sealed, lead-acid, 6 cells battery. φ on the rating label stands for phase symbol.
System Description Top -1. Power On/Off Switch 2. Green LED : AC Mode/Battery mode 3. Red LED: Fault LED 4. All receptacles are surge protected 5. Surge protection receptacles 6. Battery power supplied receptacles Side -7. AC Input 8. Breaker 9.
Installation & Operation Installing the PowerWalker VFD 600/800 APFC UPS is as easy as the following steps shown. Be aware that the Power Switch must be kept in the “ON” position and all equipment must be plugged into the Battery Power Supplied Receptacles, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping.
3. Charging This unit is shipped from the factory with its internal battery fully charged. However, some energy may be lost during shipping, so the battery should be recharged before using it. Plug the unit into an appropriate power supply, then switch on UPS and allow the UPS to charge fully by leaving it plugged in for at least 8-10 hours with no load (no electrical devices such as computers, monitors, etc.) connected.
4. Computer Connection Connect one computer-related device into one of the battery supplied receptacles on the top of UPS. PowerWalker VFD 600/800 APFC UPS provides six receptacles, all with surge protection, four of them including battery backup. 5. Peripheral Equipment Connection Plug your peripheral equipment (printer, scanners, speakers) into the full-time surge protection outlets. These receptacles do not provide any power during a power failure.
6. Modem/Phoneline Connection Plug incoming internet line into the “In” socket at the side panel of the UPS. Use one more internet line cable and plug one end of the internet line cable to the “Out” socket at the side panel of the UPS. Plug the other end of the modem input socket as shown. 7. Circuit Breaker When short circuit happens, the circuit breaker will pop-up and then the UPS will shutdown automatically.
. DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. 10. Battery Replacement CAUTION: Battery replacement should be performed by qualified service personnel. Please follow the charts below to replace the batteries. Step 1: Please prize up the battery cover gently. Chart 1 Step 2: Please remove the battery cover gently.
Step3: After removing battery cover, gently extract the battery by disconnecting the two wires connecting to the UPS. Be sure to replace the same type of batteries and dispose of old batteries properly at an appropriate recycling facility.
Specification POWER RATING 600VA/300W 800VA/420W INPUT Pure Sine Wave Range of Input Voltage 170Vac~270Vac Nominal Voltage 220Vac Nominal Frequency 50H/60HZ OUTPUT Line Mode Same as input Battery Mode Line Mode Voltage Step wave Same as input voltage Battery Mode Voltage 220Vac10% Line Mode Frequency Battery Mode Frequency Transfer time Same as input frequency 50Hz/60Hz 1Hz 2-8ms typical ,12ms Max BATTERY Battery type 600VA 800VA 12V/5Ah*1 12V/7Ah*1 Backup time 100W SPS LOAD 17min
Battery low Buzzing Per 1s Fault Continuous sounding Buzzing Per 0.5s Over load PROTECTION TVSS / Over load / Short Circuit Protection/Over charge PHYSICAL Dimension (DxWxH) Net Weight Outlets 600VA 800VA 320*125*86(mm) 335*170*92.5(mm) 3.1KG 4.1KG Schuko type/French type 6 outlets (2 for surge only, 4 for battery backup) ENVIRONMENT Operation Temperature/ Operation Humidity 0-40℃/0%-85% Trouble Shooting If the UPS failed to operate properly, please review the following points firstly.