USER MANUAL 1000VA/1500VA Line Interactive Sinewave UPS (220/230/240VAC) Version: 1.
Tabel of Contents SAFETY INSTRUCTION .................................................................... 1 1. Introduction ................................................................................ 3 2. Package Contents........................................................................ 3 3. Product Overview ........................................................................ 3 4. Installation ................................................................................. 4 5.
SAFETY INSTRUCTION Thank you for purchasing this power protection product. Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully. Transportation ⚫ Please transport the UPS system only in the original package to protect against shock and impact.
computer) to connect the UPS system to the building wiring outlet (shockproof outlet). Maintenance, service and faults ⚫ The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel. ⚫ Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous.
1. Introduction This product is an intelligent line interactive sinewave UPS (Uninterruptible Power Supply) which is designed to protect your personal computer or sensitive electronic equipment from all forms of power interference, including complete power failure. 2. Package Contents NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use.
4. Installation Before installing the UPS, please read below to select a proper location to install the UPS. ⚫ UPS should be placed on the flat and clean surface. Place it in an area away from vibration, dust, humidity, high temperature, flammable liquids and gases, corrosive and conductive contaminants. Install the UPS indoors in a clean environment, where it is away from window and door. ⚫ It’s required to maintain the maximum altitude of 1000m to keep UPS normal operation at full load UPS.
Step 1: UPS Input Connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. For the best results, suggest to charge the battery at least 5 hours before initial use. The unit charges its battery while connecting to the utility. Note: Do not expect full battery run capability during this initial charge period. Step 2: UPS Output Connection Battery Backup Outlets Connect computer and monitor to the "Battery Backup" outlets.
Step 5: Turn On the UPS Before using the UPS, be sure to remove this label from LCD remote panel module. To turn on the UPS, simply press the ON/OFF button on the front panel for 2 seconds. UPS will beep once and LED bars will light up with different colors in order of light blue, orange, yellow, green, blue, purple and scroll from bottom to top in 6 secs. Then, LCD will light on. Remote panel operation LCD panel can be removed from the base and place it closed around you when playing PC game.
5. Battery Replacement Please read all of the WARNINGS and CAUTIONS before attempting to service the batteries. Typical battery life is 3 to 5 years. Environmental factors do affect battery life. High temperatures, poor utility power, and frequent, short duration discharges have a negative impact on battery life. ⚫ WARNING! This UPS contains potentially hazardous voltages. Do not attempt to disassemble the UPS beyond the battery replacement procedure. ⚫ This UPS contains no user serviceable parts.
Please follow below steps to replace the batteries if necessary. Step 1: Turn off the equipment that is plugged into the output of the UPS. Step 2: Turn off the UPS. Step 3: Remove AC input plug of the UPS from the AC wall outlet. Step 4: Remove all equipment from the output sockets of the UPS. Step 5: Remove battery cover by loosening two screws located on the bottom of the UPS and slide the battery cover downward, then outward. Set it aside. Step 6: Disconnect the battery wires (BAT+ and BAT-).
6. Operation Button Function Button Function ON/OFF ⚫ Press and hold 2 seconds to turn on or off the UPS. ⚫ Hold “on/off” button for 10 seconds can reset the unit in case of communication failure between remote panel and UPS. ⚫ Quick press 5 times to reset pairing when wireless transmission fails. MUTE Press and hold 2 second to enable or disable mute function. UP/DOWN ⚫ Press and hold 0.5 second to switch display information. ⚫ Press and hold 2 seconds to enter the setting menu.
Load information Indicates the load level by 0-24%, 25-49%, 50-74% and 75-100%, or overload alarm. Mode operation information UPS operates on the Line mode. UPS operates on the AVR mode. UPS operates on the Battery mode. Setting of LED bars. Indicates PC’s CPU temperature (C) Setting the temperature alarm level. Indicates PC’s CPU speed(Mhz) Indicates PC’s CPU Load Indicates wireless connection matched. Indicates the remote panel is connected to docking base.
Warning Indicator Display Warning Flashing/on Alarm Over-current on output Flashing every 0.5 secs Sounding every 0.5 secs Overload Flashing every 0.5 secs Sounding every 0.5 secs Low battery Flashing every 0.5 secs Sounding every 1 sec On Sounding every 2 secs Flashing every 0.5 secs N/A Battery replacement or battery is not connected. Abnormal NiMH battery charging LCD Setting After pressing and holding “UP/DOWN” button for 2 seconds, the unit will enter setting mode.
On-Off RGB LED LED OFF LED ON(default) ENERGY SAVING Brightness of RGB LED Low Normal(default) High Low Normal(default) Scrolling speed of RGB LED High Breath(default) Effects of RGB LED Scrolling Solid Color selection of RGB LED in Line mode White Orange Yellow(default) Green Blue Purple Others Color selection of RGB LED in AVR mode 12 White Orange Yellow Green(default) Blue Purple
Others Color selection White Orange Yellow Green Blue(default) Purple of RGB LED in Battery mode Others Display Setting The LCD display information will be switched in turns by pressing “UP/DOWN” button.
Selectable Information Battery Capacity Selectable Information LCD Screen PC CPU temperature Estimated backup time CPU utilization Output Voltage Panel board firmware version Output Frequency Firmware version of docking base board Output in kW UPS control board firmware version 14 LCD Screen
7. Trouble Shooting If the UPS system does not operate correctly, please solve the problem by using the table below. Problem/Fault code Possible Cause/Fault Event Solutions UPS will not be turned on Hold the On/Off button too Press and hold the On/Off button after pressing On/Off short. for at least 2 seconds and then button. release. The mains supply is normal, Power cord is loosen. Re-connect AC input power cord. but the UPS is operating in Circuit breaker is tripped. Reset the input circuit breaker.
Fault code E20 and icon is on. Fault code E21 Fan lock fault. Contact your dealer. Over charge voltage Contact your dealer. Fault code E28 and icon is on. Low battery voltage. Fault code E43 and icon is on. Overload fault Please replace the battery. If the fault still occurs after battery is replaced, contact your dealer. Contact your dealer. icon is illuminated and The UPS has an internal a constant alarm. problem. Contact your dealer. 8.