Operation Manual

SPECIFICATION CHARTS
FUEL CONNECTION 5/16” HOSE BARB
FUEL RECOMMENDATION DIESEL FUEL No.1-D or No.2-D ASTM / D975
BATTERY VOLTAGE 12 VOLTS DC
BATTERY CRANKING AMPS 420
BATTERY COLD CRANKING AMPS 590 MINIMUM
BATTERY GROUND NEGATIVE
FUEL CONSUMPTION IN GALLONS PER HOUR
LOAD PERCENTAGE 3KW
25% .075 GPH
50% .150 GPH
75% .225 GPH
100% .300 GPH
ENGINE TEMPERATURE
* Combustion Air Temperature: The output of the engine will decrease about 1% for
every 10°F of air temperature above 77°F or 25°C.
INSTALLATION FACTORS
Each generator set is received as a unit except for the exhaust system components, remote
radiator, coolant reservoir tank and remote panel which are shipped loose for assembly after the set is
installed in the vehicle. When preplanning the installation, the following factors must be considered.
1. MOUNTING STRUCTURE: Is the vehicles mounting structure strong enough to
support the weight of the generator set?
2. FUEL SYSTEM: Is the fuel system properly designed to prevent fuel
starvation of either the main engine or generator engine?
3. EXHAUST SYSTEM: Will the exhaust system meet all applicable safety
requirements?
4. ELECTRICAL CONNECTIONS: Will all systems, (battery, load and remote switch)
be compatible with the vehicles electrical system?
4
3KW
ENGINE SPEED IN RPM 2200
OUTPUT IN HORSEPOWER 5
ENGINE INLET WATER TEMP. N/A
ENGINE OUTLET WATER TEMP.MAX. 230°F
HIGH TEMP. SHUTDOWN SWITCH 242°F
COMBUSTION AIR TEMP. * N/A