Use and Care Manual
Running the unit on voltages which are not within range 
may cause overheating and motor burn-out. Heavy loads
require that voltage at motor terminals be no less than the
voltage specified on nameplate.
• Power supply to the motor is controlled by a locking
  rocker switch. Remove the key to prevent unauthorized
  use.
GROUNDING INSTRUCTIONS
Improper connection of equipment grounding conductor
can result in the risk of electrical shock.
• The machine should be grounded while in use to protect  
  operator from electrical shock.
• In the event of an electrical short circuit, grounding   
  reduces the risk of electrical shock by providing an   
  escape wire for the electric current.
• This machine is equipped with an approved 3-conductor  
  cord rated at 150V and a 3-prong grounding type plug  
  (Figure 4) for your protection against shock hazards.
• Grounding plug should be plugged directly into a   
  properly installed and grounded 3-prong grounding-type 
  receptacle, as shown (Figure 4)
• The plug must be plugged into an outlet that is properly 
  installed and grounded in accordance with all local   
  codes and ordinances.
• Check with a qualified electrician or service personnel if 
  these instructions are not completely understood or if in 
  doubt as to whether the tool is properly grounded.
• Do not modify plug provided. If it will not fit in outlet,   
  have proper outlet installed by a qualified electrician.   
  Use only 3-wire extension cords, that have 3-prong   
  grounding type plugs and matching 3-conductor   
  receptacles that accept the machine’s plug, as show in 
  Figure 4
Figure 4 3-Prong Receptacle
Do not permit fingers to touch the terminals of plug when
installing or removing from outlet.
• Inspect tool cords periodically, and if damaged, have   
  repaired by an authorized service facility.
• The conductor with insulation having an outer surface that  
  is green with or without yellow stripes is the equipment-   
  grounding conductor. If repair or replacement of the   
  electric cord or plug is necessary, do not connect the   
  green (or green and yellow) wire to a live terminal.
A temporary 3-prong to 2-prong grounding adapter (see
Figure 5) may be used to connect this plug to a matching
2-conductor receptacle as shown in figure 5. The temporary
adapter should be used only until a properly grounded
outlet can be installed by a qualified electrician.
Figure 5 2-Prong Receptacle
In Canada, the use of temporary adapter is not permitted
by the Canadian Electric Code. Where permitted, the rigid
green tab or terminal on the side of the adapter must be
securely connected to a permanent electrical ground such
as a properly grounded water pipe, a properly grounded
outlet box or a properly grounded wire system.
• Many cover plate screws, water pipes and outlet boxes 
  are not properly grounded. To ensure proper ground,   
  grounding means must be tested by a qualified   
  electrician.
EXTENSION CORDS 
Use proper extension cords. Make sure the extension
cord is in good condition. Use only 3-wire extension cords
have 3-prong grounding type plugs and 3-pole
receptacles which accept the tool plug. When using an
extension cord, make sure to use one heavy enough to
carry the current of the machine. An undersized cord will
cause a drop in the voltage, resulting in loss of power and
overheating. Use the table to determine the minimum wire
size (A.W.G.) extension cord.
Extension Cord Length
Wire Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.W.G.
Up to 25 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
25 to 50 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
NOTE: Using extension cords over 50 ft. long is not
recommended.
MOTOR
The 120 Volt AC motor has the following specifications:
Horsepower (Peak HP) . . . . . . . . . . . . . . . . . . . . . . . . . 1/2
Voltage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Amps   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5
Hertz   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Phase   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single
RPM   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725
3
ASSEMBLY
Properly Grounded Outlet
3-Prong Plug
Grounding Prong
Ground Outlet Box
3-Prong Plug
Grounding Prong
Grounding
Means
Grounded outlet Box
Adapter
 WARNING
 WARNING