Specification
PowerStar AE115 & AE125
With more than 25 years of experience selling tankless water heaters, Controlled Energy Corporation provides
unmatched knowledge and service to its customers. Sales, service, installation, and technical information are
just a toll-free call away. Or you can visit our web site.
Controlled Energy Corporation
340 Mad River Park, Waitsfield, VT 05673 USA
Toll-free: 866-642-3199 • Fax: 802-496-6924
email: sales@ControlledEnergy.com
website: www.ControlledEnergy.com
MODEL AE115 AE125
Energy Factor .95 .95
Efficiency 95% 95%
Weight 20 lbs. 22 lbs.
Dimensions 15
1
/
4” x 15
1
/
2” x 4
1
/
2” 15
1
/
4” x 15
1
/
2” x 4
1
/
2”
Water Fittings
3
/
4” male NPT
3
/
4” male NPT
ELECTRICAL REQUIREMENTS
Volts 240/208v 240/208v
Kilowatts 17/13kw 27/20kw
Amps 80/69 (2 x 40 amps) 120/101(3 x 40 amps)
Wire Size 8 gauge 8 gauge
(4 conductors & ground) (6 conductors & ground)
Phase Single Single
MAXIMUM FLOW RATE AT GIVEN TEMPERATURE RISE
Average ground water temperature in the United States is 55˚F
45˚F Rise 2.6 gpm 4.0 gpm
50˚F Rise 2.3 gpm 3.7 gpm
60˚F Rise 2.0 gpm 3.0 gpm
70˚F Rise 1.7 gpm 2.6 gpm
80˚F Rise 1.5 gpm 2.2 gpm
NOTE: The unit will not provide an output temperature above 131˚F.
Model AE115 is not
recommended in
climates where
average ground
water temperature
is less than 60˚F.
AE125 Recommended
AE115 & AE125 Recommended
Minimum service to home for Model AE115 is 150 amps
Minimum service to home for Model AE125 is 200 amps
Important Electrical Requirements
Wire Size
gpm = Gallons Per Minute