User Manual

www.powersolve.co.uk
Powersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
AC-DC Converters
MODEL MAX OUTPUT POWER OUPUT VOLTAGE OUPUT CURRENT FAN OUTPUT STANDBY SUPPLY
NUMBER (12 CFM AIR FLOW) V1 (12 CFM AIRFLOW) V2 V3
AHP200-12 212 W 12.0 VDC 16.7 A 12.0 V/1.0 A 5.0 V/0.1 A
AHP200-24
212 W 24.0 VDC 8.3 A 12.0 V/1.0 A 5.0 V/0.1 A
AHP200-48 205 W 48.0 VDC 4.0 A 12.0 V/1.0 A 5.0 V/0.1 A
MODELS
AND RATINGS
MECHANICAL DETAILS
Notes:
1. All dimensions in inches (mm).
2. Units supplied with screw terminal (CN2) as standard. For faston type, add suffix ‘-F’ to the part number.
3. All 4 mounting positions should be connected to safety earth.
4. The air flow needs to be directed through the power supply within the end application.
AIR
FL
OW
12
CFM
5.00 (127.0)
4 X
ø
0.14 (3.5
) MO
UNT
ING H
OLE
S
SAFE
TY
EA
R
TH
- 4.8
mm
Faston
SCRE
W
TYP
E
6.35
mm
F
AST
ONT
YPE
(2)
4.55 (115.6)
0.22
(5.7)
CN1
CN3
1
1
5
10
6
2
CN2
+ve
-ve
CN2
N
L
2.55
(64.8)
3.00
(76.2)
1.22
(31.0)
0.06
(1.5)
0.06 (1.5)
TR4
T7
C42
C14
TR1
1
1
2
CN2
(See Thermal
considerations)
Pin 1 +V
Pin 2 V1 Return
Pin Connections - CN2
1 +V2
2 V2 Return
3 V2 Return
4
ROF
5 ROF Return
6
Power Fail/DC OK
7
Current Share
8 +V3
9 -V3
10
+V2
Pin Connections - CN3
Mating Connectors:
CN1: Molex housing 09-50-3031 and crimp 2878.
CN3: Molex housing 51110-1050 and crimp 50394-8100.
THERMAL
CONSIDERATIONS
Mating Connectors:
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. See
drawing above for component locations. The temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any
direct air flow).
Component
Max Continuous Temperature ºC
TR4 case 110 ºC
C14 105 ºC
C42 105 ºC
TR11 case 110 ºC
T7 coil 120 ºC
Temperature Measurements (Ambient 50 ºC)