Owner's manual

600S24
Page 2 SPECIFICATIONS Rev. Sept. 2012
Under voltage alarm contact : Changes over when output voltage drops Overload Protection: Continuous overload and short circuit
to 10% below the the set value. protection does not harm the unit. At
Gold contact, rating 100 mA/30 V. short circuit the power supply
Remote control : Is possible with a 10 k potmeter. produces an audible bleep.
Remote programming : Output voltage is programmable with 2-5 V, Voltage limit : For safety an extra regulation circuit limits
corresponding with 12-30 V. Programming the output voltage to about 31 V in case
speed is 100 ms from 12-30 V at max current. of malfunction of the normal regulation.
Programming input is not isolated (connected This limit is internally adjustable 20-31 V
to - output). (R111).
Remote sensing : max. 3 V per load lead. However the sum of Overtemp. pro- : With insufficient cooling the
the voltage across load + leads cannot tection shuts down.
exceed 30 V. Led lamps : Green LEDs on front and rear panel
With parallel operation remote sensing is not indicate output voltage.
recommended. Wall mounting : Any position, as long as the air can flow
Remote on/off ` : By 5 V, optocoupler isolated. freely along the unit for cooling.
Ambient temperature
Storage : -40 to + 85 °C
Operating : -20 to + 60 °C
Derate to 20% at 75 °C
Tem per a ture derating
Two ways of ver ti cal mounting
Current limit : From 30 to 18 V the current limit follows 19" rack mounting : With two brackets H88 with handle the
more or less a constant power curve.Below unit can be 19" rack mounted
18 V it resembles a constant current curve. (2U height)
MTBF : 1.000.000 hrs
Dim and weight : Height 88mm
Width 433 mm
Depth 385 mm
Weight 10.5 kg
Nor mal cur rent limit and de rat ing at
low in put volt age.
Cover of con nec tion panel.
Bracket H88 for ver ti cal
wall mount ing
(2 pcs re quired )
Bracket H88 with han dle
for 19" rack mounting
(2 pcs re quired )
Bracket H114 for ver ti cal
wall mount ing.