MANUAL START THE ENGINE
To manual start the generator, perform the following steps:
1. Unplug all electrical devices from the generator during ignition. Otherwise
it will be difficult for the engine to start.
2. Check that the generator is properly grounded (Refer to “GROUND THE
GENERATOR”).
3. Check the oil and fuel levels.
4. Turn the fuel valve to the “ON” position.
5. Move the choke lever to the “CLOSE” position.
6. Set the ON/OFF Switch to the “ON” position.
7. Pull on the recoil starter handle slowly until a slight
resistance is felt, then pull quickly to start the engine.
Return cord gently into the recoil starter. Never allow the
cord to snap back.
8. If engine fails to start, repeat step 7. NOTE: After
repeated failed attempts to start the engine, please consult
the troubleshooting guide before attempting again. If problems
persist, please call (800) 791-9458 M-F 9am-5pm EST.
9. Once the engine has started, slowly return the choke lever all the
way to the “OPEN” position.
10. Allow the engine to run for several minutes before attempting to
connect any electrical devices. This allows the generator to
stabilize its speed and temperature.
ELECTRIC START THE ENGINE
To start the generator using the electric start function, perform the following steps:
1. Make sure no electrical devices are connected to the generator. Such devices can make it difficult for
the engine to start.
2. Check that the generator is properly grounded (Refer to “Ground the Generator”).
3. Check the oil and gas levels.
4. Turn the fuel valve to the “ON” position.
5. Move the choke lever to the “Start” position.
6. Set the engine switch to the “ON” position.
7. Press the engine switch to the “START” position for 2-3 seconds or until the engine starts. NOTE: If
the engine does not start after 2-3 seconds, release the switch from the start position. Keeping the
switch in the START position too long can damage the starter.
8. If engine fails to start, wait 10 seconds, then repeat step 7. NOTE: After repeated attempts to start the
engine, please consult the troubleshooting guide before attempting again. If problems persist please
call (800) 791-9458 Mon-Fri 9-5 EST.
9. Once the engine has started. Slowly move the choke lever all the way to the “Run” position. Allow
the generator to run for several minutes before attempting to connect any electrical devices.
Engine Switch