STARTING THE ENGINE
To start the generator, perform the following steps:
1. Unplug all electrical devices from the generator during ignition. Otherwise
it will be difficult for the engine to start.
2. Check that the generator is properly grounded (Refer to “GROUND THE
GENERATOR”).
3. Check the oil and fuel levels.
4. Turn the fuel valve to the “ON” position.
5. Move the choke lever to the “CLOSE” position.
6. Set the ON/OFF Switch to the “ON” position.
7. Pull on the recoil starter handle slowly until a slight
resistance is felt, then pull quickly to start the engine.
Return cord gently into the recoil starter. Never allow the
cord to snap back.
8. If engine fails to start, repeat step 7. NOTE: After
repeated failed attempts to start the engine, please consult
the troubleshooting guide before attempting again. If
problems persist, please call (800) 791-9458 M-F 9am-5pm EST.
9. Once the engine has started, slowly return the choke lever all the way to the “OPEN” position.
10. Allow the engine to run for several minutes before attempting to connect any electrical devices. This
allows the generator to stabilize its speed and temperature.
STOPPING THE GENERATOR
TO STOP THE GENERATOR
1. Turn off all electrical devices prior to unplugging them from the generator. Unplugging running
devices can cause damage to the generator.
2. Turn the “ON/OFF” switch to the “OFF” position.
3. Turn the fuel valve to the “OFF” (horizontal) position.
WARNING: Allow the generator to cool for several minutes before touching areas that
become hot during use.
CAUTION: Allowing gasoline to sit in the fuel tank for long periods of time can make it difficult to start
the generator in the future. Never store the generator for extended periods of time with fuel in the fuel