System Maintenance n
Routinely (twice a year) perform the following maintenance to
ensure safe continuous operation of ESP Hydropanel™ units.
1. Inspect electrical connections for corrosion.
2. Check for any loose connections. Tighten if necessary.
3. Check solenoid valve for proper operation. Make sure it is
free of dirt and lime build up.
4. Check that temperature of supply water is thermostatically
controlled for safe comfortable bathing.
For brass solenoid: For maintenance instructions, use Powers
Kit #444 183 and refer to “Installation and Maintenance
Instructions,” Series 8210, included with the ESP Hydropanel™
II Kit.
Parts List n
No. Part # Description
1 444 416 Sensor Assembly for Pushbutton Shower
1A 444 416 Pushbutton Assembly
2 444 175 Solenoid Assembly (non-metallic)
3 444 175 Solenoid Assembly (brass)
4 444 161 Control Box, Individual Pushbutton Showers
5 444 118 Plug In Transformer
6 444 119 Box Transformer
No. Part # Description
7 141 379 Swivel Showerhead
8 141 816 Fixed Showerhead
Not Shown 444 168 Installation Kit, Pusbutton Control Box
Not Shown 444145C Maintenance/Repair Kit, Solenoid (non-metallic)
Not Shown 444145D Diaphragm Repair Kit, Solenoid (non-metallic)
Not Shown 444 183 Maintenance/Repair Kit, Solenoid (brass)
Solenoid Valve Maintenance n
Maintenance and Troubleshooting n
65
4
3
7
8
1
1a
2
The following are problems that may occur with the ESP
Hydropanel™ II. Follow the listed steps toward a solution. For
any further problems, call Powers Application Engineering
Deptartment at 1.800.669.5430.
Shower Control:
1. If the shower does not activate when the pushbutton
is pressed:
a. Check that transformer feed wires are securely
attached to terminals at control box and at transformer.
b. Check that power is supplied to the transformer. Also,
use a voltmeter to check that power is being supplied
through the transformer. If power goes into the trans-
former but does not come out, replace the transformer.
2. If no water flows from showerhead when pushbutton
is pressed:
a. Check that the supply line is open and water is being
supplied.
b. Check that the solenoid wires are securely connected.
c. The maximum run-time may have elapsed. Wait 5
seconds for sensor delay, then press the pushbutton
again. For a longer shower-run time, reset potentio-
meter on control box.
3. If water runs continuously, regardless of sensor activity:
a. FIRST unplug solenoid from the control box.
b. If water continues to run...
• Debris and/or lime build-up may be preventing
solenoid from closing. Dismantle, clean and flush the
solenoid valve (see Solenoid Valve Maintenance).
c. If water stops after disconnecting power...
• The problem is electronic. Check that power wires
are connected properly in the Control Box, and check
all electrical connections.