Install Instructions

For Non-Health Hazard Applications
Job Name
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
Powers product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Powers Technical Service. Powers reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Powers products previously or subsequently sold.
ES-P-141_600B-E-F
In-Line Diverter Valves
141-600B, 141-600E & 141-600F
Description
HydroGuard
®
3-port, in-line diverter valve pro vides smooth transfer of
water from one outlet (showerhead) to another (hand shower or tub spout).
Compatible with all Biltmore 900, HydroGuard 410, HydroGuard T/P
Series e700 and e420 tempering shower valves.
Valve features:
• Cast bronze body.
• Chrome-plated zinc die-cast, ABS, ADA-compliant handles.
• Stainless steel faceplate.
• Easy-to-read graphic insert.
Specifications
ADA-compliant handles
Standard Metal Handle
141-600B
Deluxe ABS Handle
141-600E
Deluxe Metal Handle
141-600F
Connections ............................. ½" sweat inlets and outlet
Capacity ................................ 6.0 gpm @ 45 psi differential
(23 L/min @ 310 kPa)
Maximum Inlet Temperature ................. 180°F [82°C]
Maximum Operating Pressure ................ 125 psi [862 kPa]
Agency Approvals ......................... ADA-compliant handle
Certified ................................. CSA-B125
Shipping Weight .......................... 3.0 lbs [1.4 kgs.]
Typical Installation
Inches (Millimeters)
1-7/16 [37] min.
3 [76] max.
8 [203] min.
Wall opening
4 [102] dia.
Wall
All dotted line piping supplied by others.
4-3/4
[121]
78 [1981]
approx. to
finished floor
1/2-14 NPT
male inlet
141-600B Diverter
Valve
78 [1981]
approx. to
finished floor
48 [1219] to floor
(typical)
38 [965] to floor
(typical)
P
O
W
E
R
S
P
R
O
C
E
S
S
C
S
L
D
I
V
E
R
T
E
R
POWERS
H
C
OFF
5-1/2
[140]
78 (1981)
approx. to
finished floor
48 (1219) to floor
(typical)
Wall opening
4 (102) dia.
Valve
8 (203) min.
1-
7
/16 (37) min.
3 (76) max.
Wall
141-600B Diverter
½ – 14 NPT
male inlet
78 (1981)
approx. to
finished floor
38 (965) to floor
(typical)
4-¾
(121)
5-½
(140)
All dotted line piping supplied by others.