Operation Manual

POWLI231 EN
Copyright © 2016 VARO P a g e | 2 www.varo.com
that the packing tightens. The packing can be adjusted to a cable diameter of 8-11
mm.
If you want continuous light you can add a switch. Please consult fig 4
4.3 Mounting
Check the correct way of mounting in fig 1.
Check the safety distance between the body and inflammable surface when wall or
corner mounted in fig. 2.
5 USING THE FLOODLIGHT
Turn the power back on.
6 SETTING THE LIGHT SYSTEM (FIG. 5)
6.1 Test mode
Turn the LITE control and the Time control anticlockwise to the edge (the TEST
position).
Set the SENS. Control to its mid-point.
Turn on the wall switch. The floodlight will turn on for about 1 minute to warm up.
Then it turns off.
Walk through the detection area. The floodlight turns on when you move and turns off
when you stop. Wait for the floodlight to turn off before moving again to test the
sensor.
Adjust the motion sensor to cover the desired detection area.
For a smaller coverage area, point the sensor down; for a larger coverage area, point
the sensor up.
6.2 TIME adjustment
The TIME adjustment controls how long the floodlight will stay on after the motion
has been detected.
Turn the TIME control knob clockwise to increase (up to about 12 minutes) how long
the floodlights stay on or anti-clockwise to decrease (down to about 5 seconds) the
time delay.
6.3 LITE adjustment
The LITE adjustment determines at what light level the lighting system will start
operating when you set the sensor to Automatic Operation.
Provisionally turn the LITE control knob to the edge clockwise at the moon (dusk)
position. In this provisional setting mode, the motion sensor remains inactive during
daylight. At dusk when you find it is the LUX level desired for operation, simply set
the LITE control knob to the position that the motion sensor will become active as
daylight declines.
6.4 SENS. adjustment
The sensitivity adjustment may be adjusted to compensate for seasonal variations in
temperature and to reduce unwanted triggering. The optimum sensitivity can be achieved
by setting the SENS. control knob initially to its mid-point and then adjusting the control