§ Allow engine to cool down
Emergency stopping : Turn the engine switch to “OFF”. The engine will
stop immediately.
10.4 Operating time
Depending on the type you’re using, if you start with a full tank and let it run continuously, your
generator will run approximately :
Fuel tank capacity Operating time
POW4761(SC) 15liters 13 h
The Petrol level display on top of the fuel tank shows you approximately how much petrol
there is left in the tank:
"F" Full
"E" Empty
11 MAINTENANCE/CLEANING
NOTE: Before cleaning or maintenance of the generator, you must switch off the motor and
allow the equipment to cool down!
CLEANING: For cleaning the housing, please use only a lint-free cloth dampened with a
solution of soapy water (solution of washing-up liquid). During cleaning, no water should
penetrate the inside of the generator.
11.1 Maintenance chart
Regular maintenance is most important for the best performance and safe operation.
Item Remarks
Pre-
operation
check
Every 3
months
or 50h
Every 6
months
or 100h
Every 12
months
or 300h
Spark Plug Check condition adjust gap
and clean. Replace if
necessary.
l
Engine Oil Check oil level l
Replace
l
Air Filter Clean. Replace if
necessary.
l
Fuel Filter Clean fuel cock filter.
Replace if necessary
l
Valve
Clearance
Check and adjust when
engine is cold.
l
Fuel Line Check fuel hose for crack
or damage. Replace if
necessary.
l
11.2 Engine oil replacement
Old oil, even in small quantities, must be brought to a suitable collection point for disposal. Old
oil may not be disposed of with household rubbish, waste water, or even to nature.
You need a 12 mm screw wrench and a recipient of sufficiant capacity to catch the oil (see oil
tank capacity) This recipient must fit below the oil drain bolt (if necessary raise the generator
horizontally on blocks or bricks)
§ Place the, preferably warm machine on a level surface (warm up the engine for several
minutes if cold).