TABLE 6. GEYSER ELEMENT & THERMOSTAT COMPATIBILITY GUIDE
Element type
Compatible thermostat type
Comments
Screw-in element:
VKF-11 thermostat:
Element & thermostat have separate electrical connections,
so each can be connected (wired) separately to the Elon®.
Thus, this element-thermostat combination is directly
compatible with the Elon®. (No need to use the bridging
wire or element adapter supplied with the Elon® unit.)
The thermostat pocket in the element is the right size for
the VKF-11 thermostat.