Element type
Compatible thermostat type
Comments
Spiral element (flange type) with smaller diameter
thermostat pocket:
TSE thermostat: Thermowatt (RTS) thermostat:
The spiral element generally has a smaller thermostat
pocket than the screw-in element. The TSE and Thermowatt
(RTS) thermostats fit into this smaller pocket. The VKF-11
thermostat requires a larger pocket and does not fit into
standard spiral element pockets.
The TSE and Thermowatt thermostats normally clip directly
into the element, but this won’t be the case when the Elon®
is connected.
Use the bridging wire and element adapter supplied with
the Elon® (see the Installation Guide) to connect the Elon®
to these thermostats and elements.