CONTROL PANEL FUNCTIONS
WARNING!
WARNING!
Never connect generators that are different models.
Generator must be properly grounded to prevent electrocution.
Only connect this generator to another PMG4000iS Standard Generator.
Only use a parallel operation cable kit designed to work with this Generator
The generator’s ground terminal must always be used to connect the generator
to a driven ground rod. Connect the ground terminal to the driven ground rod
with a 12 AWG (American Wire Gage) copper wire. The wire connects to the
terminal between the lock washer and nut. Tighten the nut securely to ensure
good connection. Grounding the generator protects you from electric shock
that results from a build up of static electricity or undetected ground faults.
Turn counterclockwise to remove the fuel tank cap.
Located just above the Ground Terminal, the generator’s Parallel Outlets enable a user to run two
PMG4000iS generator’s simultaneously. This operation requires special cables. When operating parallel
generators, the rated output is 7.0kVA and the rated current is 58.3A/120VAC. For cables and instructions
consult a PowerMax dealer for a PARALLEL OPERATION CABLE KIT.
Note: The Economy switch must be turned to the “OFF” position when using electronic devices that require
a large starting current, such as a compressor.
Only operate generator on a level surface.
Always connect the nut and ground terminal on the frame to an appropriate ground source.
Ground Terminal
Fuel Tank Cap
Parallel Outlets