Spec Sheet

EPseries
WPS800S
50Hz@1500rpm,3-phase/5-wiring
1Standards&Conditions
DesignStandards
Thedesignsandtheproductionsareinconformitywith:
ConformiteEuropeenne(CE)
ChinaCompulsoryCertication(CCC)
ISO8528-5:2005
GB/T2820.5-2009
EnvironmentalOperatingConditions
Installationplace:Outdoorsorindoors(wellventilated).
Ambienttemperature:-25to50.Thecoolantheater
isneededwhenthetemperatureisbelow5
Humidity:Lessthan80%.
Altitude:Belowonethousand(1000)meters.
FactoryInspection
Inspectionitems.
Protectiondevicesworkingtest.
Startingabilityinnormaltemperature.
50%ratedpowerloadmomentcapability.
Voltagedeviationandspeedvariation:0%,25%,50%,
75%,100%,110%Load.
PaintingProcess
Paintingprocessspecicationsandcolorsarebasedon
themanufacturer'sstandard.
Thecustomercouldalsochoosethecolorwhichthe
manufactureroffers.
2GeneralFeatures
Perkinsengine4006–23TAG3A
ClosecoupledtoaLeroySomeralternatorLSA49.1M75
MicroprocessorcontrolmodulePLC-7420
DMAmaincircuitbreaker:1250A
Rotatespeedgovernor:Electronicgovernor
Excitationsystem:Selfexcited
A.V.Rmodel:R448
Keyswitch
Emergencystopswitch
ATS(automatictransferswitch)receptacle
2x12V/150AHsealedforlifemaintenancefreebattery
Lockablebatteryisolatorswitch
Powdercoatedcanopy,IP43dripprotectionclass
50radiator
Fireextinguisher
Oilpumpontheengine
Steelbaseframewithforkslots
Vibrationisolatorsbetweentheengine/alternatorand
baseframe
Drytypeairlter
Fueltankfor8hoursrunning
Fuelinletpumpandit’scontrolboxforthefueltank
Addedfuel-waterseparatorforfueltank
Drainpointsforfueltank
OperationManual/Specications
3EquipmentSpecication
Generaltechnicaldata
Model...................................................................WPS800S
Structuretype....................................................................C
Tankcapacity..............................................................1450L
Dryweight...............................................................10895kg
Soundpressurelevel@7m..............................106.75dB(A)
Soundpowerlevelacc.2000/14/EC.................134.6dB(A)
DimensionsL×W×H............................6058×2438×2730mm
StandbyPower............................................880kVA/704kW
PrimePower................................................800kVA/640kW
Voltage380V400V415V440V
Ampere1215.5A1154.7A1112.9A1049.7A
GensetFuelConsumption
Frequency/Load25%50%75%100%110%
50Hz(L/h)N/A85.5123.5163.4184.3