Product Manual
Engine (cont’d)
42
Maintenance
schedule
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by an authorized generator service center, unless the owner
has the proper tools and is mechanically proficient.
REGULAR SERVICE
PERIOD
Before
each use
First
month or
20 Hrs.
Every 3
months or
50 Hrs.
Every 6
months or
100 Hrs.
Every
year or
300 Hrs.
Engine Oil
Check level
○
Change
○
○
Oil Filter
Replace
Every 200Hrs.
Air Filter
Check
○
Clean
○(1)
Replace
○
Fuel Valve
Sediment
Cup
Clean
○
Spark Plug
Check-adjust
○
Replace
○
Spark
Arrester
Clean
○
Idle Speed
Check-adjust
○(2)
Valve
Clearance
Check-adjust
○(2)
Cylinder
Head
Clean
After every 300Hrs. (2)
Fuel Tank
and Filter
Clean
Every 2 years (Replace if necessary) (2)
Fuel Tube
Check
Every 2 years (Replace if necessary) (2)
Engine oil
recommendations
CAUTION: Engine damage
The generator has been shipped WITHOUT oil. Any attempt to start generator without oil
may result in engine damage and failure.
Engine oil is a key factor in deciding the engine’s performance. DO NOT use engine
oil with additives or 2-stroke gasoline oil, as they lubricate properly, which may
shorten the engine’s service life.
Check the engine oil level with the generator stopped on a level ground.
Due to viscosity variances with regions and temperatures select the correct type of oil
using the chart below.
Engine oil recommended: SAE10W-30