Product Manual
Power Load Planning & Management 
16 
 WARNING 
NEVER exceed the rated wattage capacity of your generator. 
OVERLOADING may cause SERIOUS DAMAGE to the generator and 
attached electrical devices, and may result in fire. 
Your generator MUST BE SIZED PROPERLY to provide both the running and starting (surge) 
wattage of the devices you will be powering. Before using your generator, determine the running 
and starting wattage requirements of all the electrical devices you will be powering simultaneously. 
The sum of the running and starting wattages of the devices being powered must not exceed the 
continuous output rating of your generator.  (The continuous output rating of your generator is listed 
in the “Specifications” section of this manual.) Note that: 
•  Devices without electric motors such as light bulbs, radios, and televisions have the same 
running and starting wattage. 
•  Devices with electric motors such as refrigerators, compressors, and hand tools typically 
require a starting wattage that is 3 to 5 times greater than the running wattage. 
The running and starting wattage requirements are often listed on a device’s nameplate. If wattage 
is not given on the device’s nameplate, the wattage may be calculated by multiplying the nameplate 
voltage by nameplate amperage, Watts = Volts X Amps. 
Example conversion to watts: 
120 Volts X 5 Amps = 600 Watts 
If only the running voltage is given on the nameplate for a device with an electric motor, the starting 
wattage can be approximated to be three to five times the running wattage. 
Estimates for the running wattage requirements for common devices are listed in Table 1 below. 
Guidance for starting wattages is provided in the table’s footnotes. 
Table 1 
Device 
Running Watts 
(Continuous) 
Starting Watts 
(Surge) 
10in. Table Saw 
1800 
4500 
7-1/4in. Circular Saw 
1400 
2300 
8in. Bench Grinder 
1400 
2500 
Air Conditioner - Central (24,000 BTU) 
3800 
4950 
Air Conditioner - RV (13,500 BTU) 
1500 
3000 
Air Conditioner - Window (10,000 BTU) 
1200 
2200 
Battery Charger: 100 Amp with 300 Amp Boost 
2400 
7800 
Battery Charger: 15 Amp 
380 
- 
Battery Charger: 60 Amp with 250 Amp Boost 
1500 
5750 
Belt Sander 
1200 
2400 
Ceiling Fan 
800 
1200 
Clock Radio 
100 
- 