Product Manual
9
Initial Set-up
10. Replace hydraulic oil fill/vent cap.
11. Start engine and use control valve handle to extend and retract wedge five (5) times to
remove air from the high-pressure lines.
12. With wedge retracted, check oil level again. Fill if necessary.
WARNING: NEVER remove the hydraulic oil dipstick when the engine is running or hot.
Hot oil can escape causing severe burns. Allow log splitter to cool completely before
removing hydraulic oil dipstick.
Note: If the log splitter will be run for long periods of time in outdoor temperatures above 70°F,
we recommend changing the hydraulic oil to DEXRON III.
Step Four: Lubricate
Beam
Apply grease to beam. This will help prevent wear between the wedge and beam.
Apply grease to beam