Product Manual
58
Assembly Instructions
Step 20 - Fittings
• Screw finger-tight (1) Return Line Fitting into the return line filter head
• Wrench-tighten the fitting to 1.5-3.0 turns past “finger tight” position. Consider
final orientation position as to not exceed the recommended TPFT. Properly
assembled fittings total thread engagement should be 3.5-6 turns
• CAUTION: Never back off an installed pipe fitting to achieve proper alignment.
Loosening installed pipe fittings will corrupt the seal and contribute to leakage
and failure.
• Connect the end of the suction hose to the pump inlet.
• Secure the low pressure return hose to return line fitting with supplied hose
clamp installed on hose. Torque to 77 in.-lb.
Tools Needed
• Flat Blade Screw
Driver
• Crescent Wrench
OR
• 1 1/16” Wrench
Fasteners Needed from Parts Bag:
Return Line Fitting
Qty: 1
1 3/8” Wrench
Return Line
Filter Head
Return
Line
Fitting
Suction Hose
Hose Clamp
Pump Inlet