Assembly Instructions
Step 20 - Fittings
Screw finger-tight (1) Return Line Fitting into the return line filter head
Wrench-tighten the fitting to 1.5-3.0 turns past “finger tight” position. Consider
final orientation position as to not exceed the recommended TPFT. Properly
assembled fittings total thread engagement should be 3.5-6 turns
CAUTION: Never back off an installed pipe fitting to achieve proper alignment.
Loosening installed pipe fittings will corrupt the seal and contribute to leakage
and failure.
Connect the end of the suction hose to the pump inlet.
Secure the low pressure return hose to return line fitting with supplied hose
clamp installed on hose. Torque to 77 in.-lb.
Tools Needed
Flat Blade Screw
Driver
Crescent Wrench
OR
1 1/16” Wrench
Fasteners Needed from Parts Bag:
Return Line Fitting
Qty: 1
1 3/8” Wrench
Return Line
Filter Head
Return
Line
Fitting
Suction Hose
Hose Clamp
Pump Inlet