Product Manual

3
Scroll Air Compressors Tankmount/Basemount
Breathable Air Warning
This compressor/pump is not equipped and should
not be used “as is” to supply breathing quality air.
For any application of air for human consumption,
you must fi t the air compressor/pump with suitable
in-line safety and alarm equipment. This additional
equipment is necessary to properly fi lter and purify
the air to meet minimal specifi cations for Grade D
breathing as described in Compressed Gas Association
Commodity Specifi cation G 7.1 - 1966, OSHA 29 CFR
1910. 134, and/or Canadian Standards Associations
(CSA).
DISCLAIMER OF WARRANTIES
IN THE EVENT THE COMPRESSOR IS USED FOR THE
PURPOSE OF BREATHING AIR APPLICATION AND
PROPER IN-LINE SAFETY AND ALARM EQUIPMENT
IS NOT SIMULTANEOUSLY USED, EXISTING
WARRANTIES SHALL BE VOIDED, AND POWEREX
DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY
LOSS, PERSONAL INJURY OR DAMAGE.
HOURMETER
The hourmeter on the scroll compressor indicates the
actual number of hours the unit has been in operation. The
hourmeter is also used to determine maintenance and service
timing. An hourmeter must be installed with every
Scroll compressor.
CONDENSATE DRAIN VALVE
A condensate drain valve must be installed on every tank
to allow removal of the liquid which will collect during
compressor operation.
Drain liquid from tank daily.
Safety Guidelines
This manual contains information that is very important
to know and understand. This information is provided for
SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help
recognize this information, observe the following symbols.
Danger indicates an imminently hazardous
situation which, if not avoided, WILL result
in death or serious injury.
Notice indicates important information,
that if not followed, may cause damage to
equipment.
NOTE: Information that requires special attention.
Installation
RECEIVING THE UNIT
Immediately upon receipt of the scroll compressor, the
unit should be inspected for any damage which may have
occurred in shipment. Any shipping damage must be
immediately fi led with the freight carrier.
The compressor nameplate should be checked to see if the
unit is the correct model and voltage as ordered.
APPLICATION
When the scroll compressor is to be used in applications
other than the compressing of atmospheric air, please contact
a Powerex representative for engineering and warranty
information at 1-888-769-7979.
INSTALLATION SITE
1. The scroll compressor must be located in a clean, well lit
and well ventilated area.
2. The area should be free of excessive dust, toxic or
ammable gases, moisture, water and direct sunlight.
3. Never install the compressor where the ambient
temperature is higher than 104° F or where humidity is
high.
MINIMUM CLEARANCES
Above 24 inches
Drive belt side 12 inches
Other sides 20 inches
4. Clearance must allow for safe, effective inspection and
maintenance.
5. If necessary, use metal shims or leveling pads to level the
compressor tank or basemount unit. Never use wood to
shim the unit.
VENTILATION
1. If the scroll compressor is located in a totally enclosed
room, an exhaust fan with access to outside air must be
installed.
2. Never restrict the cooling fan exhaust air.
3. Never locate the compressor where hot exhaust air from
other heat generating units may be pulled into the unit.
WIRING
Refer to the general product manual. All electrical hook-ups
must be performed by a qualifi ed electrician. Installations
must be in accordance with local and national electrical
codes.
Use solderless terminals to connect the electric power source.