Product Manual

6
Scroll Air Compressors Tankmount/Basemount
Maintenance
Operating Hours
Item Action needed 500 2500 5000 10,000 15,000 20,000 30,000 Remarks
Pump Replace
Tank Drain moisture Daily
Inlet air fi lter Inspect,
Replace
●▲
(Every 2,500 hrs or less) Element
Part #
ST073921AV
Blower fan Clean
●●●
Fan duct Clean
●●●
Compressor fi ns Clean
(Every 2,500 hrs or less)
Bearings Grease
▲▲
Service Center Only
Bearings Grease
▲▲▲
Service Center Only
Tip seal Replace
▲▲
Every 10,000 hours
Tip seal Replace
▲▲▲
Every 5,000 hours
Heat insulation
pipe
Replace
▲▲
Every 10,000 hours
Heat insulation
pipe
Replace
▲▲▲
Every 5,000 hours
V-belt Inspect,
Replace
* Note
3
▲▲▲
Pressure switch Confi rm
operation
●●
Magnetic
starter
Inspect
●●
Replace if contact
points deteriorated
Safety valve Confi rm
operation
(Every 2,500 hrs or every 6 months,
whichever comes fi rst)
Pressure gauge Inspect
(Every 2,500 hrs or less)
Inspect
Replace
Maintenance requirements for high pressure units.
Notes: 1. Inspect and perform maintenance periodically according to maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are
adverse, shorten the cycle time and do maintenance accordingly.
3. * The tension of the V-belt should be adjusted during the initial stage and inspected every 2,500 hours afterwards.
Proper belt tension for 3 HP units is 7 lbs/0.19” defl ection; for 5 HP units, 7 lbs/0.19” defl ection.