Spec Sheet
Enclosed Scroll Air Compressor System
SEH, SEO – 30-40 HP
Powerex • 150 Producon Drive • Harrison, OH 45030 • USA
P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com
01/2017
Page 2 of 2
made of copper tube construcon and fully insulated. Dryers shall
have power on and high temperature lights, sucon pressure gauge,
internal 3-micron lter/separator with stainless steel bowl, and med
electric condensate drain. Refrigerated dryers are to be powered
from a separate supply, not through the compressor controls.
Oponal Dewpoint Monitor
NOTE: Installed on desiccant dryer.
The system-integrated hygrometer shall be equipped with an
LCD dewpoint display and high dewpoint alarm with dry contacts
for remote monitoring. The sensor shall include an auto calibraon
feature to ensure the accuracy of the dewpoint measurement.
Oponal Moisture Separator
The moisture separator shall be sized for the peak calculated
demand and shall include an auto oat drain to purge the collected
moisture.