Spec Sheet

Enclosed Scroll Air Compressor System
SED, SET, SEQ – 10-20 HP
Powerex 150 Producon Drive Harrison, OH 45030 USA
P 1.888.769.7979 F 513.367.3125 www.powerexinc.com
01/2017
Page 2 of 2
dryer is supplied with two stages of ltraon. The pre-lter removes
parculates and liquids and includes an element change indicator and
automac condensate drain. The 0.5 micron aer lter includes an
element change indicator. Dryers shall be powered through a separate
control circuit and not through the compressor controls.
Oponal Refrigerant Air Dryer
The refrigerated air dryers are non-cycling, direct expansion type,
using R-134 A refrigerant (CFC free). A hot gas by-pass system maintains
a consistent temperature at all load condions. Heat exchangers are
made of copper tube construcon and fully insulated. Dryers shall
have power on and high temperature lights, sucon pressure gauge,
internal 3-micron lter/separator with stainless steel bowl, and med
electric condensate drain. Refrigerated dryers are to be powered
from a separate supply, not through the compressor controls.
Oponal Dewpoint Monitor
NOTE: Installed on desiccant dryer.
The system-integrated hygrometer shall be equipped with an
LCD dewpoint display and high dewpoint alarm with dry contacts
for remote monitoring. The sensor shall include an auto calibraon
feature to ensure the accuracy of the dewpoint measurement.
Oponal Moisture Separator
The moisture separator shall be sized for the peak calculated
demand and shall include an auto oat drain to purge the collected
moisture.
Oponal Heat Manager
The Heat Manager fan system integrates with the Enclosed Scroll
compressor unit to facilitate the ow of cooling air into an exhaust
duct connected to the enclosure and removes the hot air out of the
room or vicinity of the compressor unit. The cooling fan will operate
when any pump inside the enclosure is running. The Heat Manager
saves energy costs and ensures reliable compressor operaon.