Owner's Manual

5.
Fasten
the inverter to the mounting surface using
corrosion-resistant fasteners sized #10 or larger.
CONNECTING THE INVERTER
This inverter has two
DC
cable connections, one
positive and one negative. The order of steps in the
following procedure minimizes the danger of sparking
near the battery bank.
1 . Prepare all cable set ends with ring terminals at the
battery ends.
2.
Install
one
fuse
holder with
fuse
on the
Positive
cable
close to the battery bank end.
3.
Make
sure the
ON/OFF
switch located on the front
panel of the inverter is in the
OFF
(0) position.
4.
Ensure all appliance cords or extension cords are
disconnected from the inverter.
5. Connect a
#8
gauge stranded insulated wire to the
enclosure ground terminal and connect the free
end
of the wire to the vehicle's chassis or any other
ground point.
6.
Connect the unfused cable to the
Negative
(-)
terminal of the battery bank.
7.
Connect the Negative cable to the Inverter's
Negative
(-)
terminal.
8.
Insulate the
end
of cable to
be
connected to the
Positive
(
+)
Inverter terminal.
9.
Connect the fused cable to the battery bank
Positive
( +) terminal.
10.Connect the
Positive
cable end to the Positive(+)
inverter terminal.
_
,Fuse
Holder
/Circuit
Breaker
(±)
-c:::S--------
RED
(±)
Battery
Inverter
e
----------
BLACK
e
19