User manual PowerBox Source

www.powerbox-systems.com
7
d) Resetting residual capacity
After each charge process it is important to reset the residual capacity dis-
play. The crucial factor determining the remaining battery charge is always
battery voltage, and the capacity display can also be very helpful in detecting
defective or ageing batteries. For example, if little capacity has been drawn
from the pack, but the voltage display already indicates a at battery, it is
essential to check that battery.
The residual capacity can be reset by holding buttons I and II pressed in si-
multaneously for about two seconds.
3. SPECIFICATION
Operating voltage 4.0V - 9.0V
Power supply 2S LiPo, 2S LiIon, 2S LiFePo, 5S NiCd/NiMH
Current drain Power-on state 85mA
Current drain Standby 10µA
Maximum load current Peak 2x20A
Drop-out voltage 0.3V
Output voltage 5.9V / 7.4V / 7.8V / 8.4V
Screen OLED 128 x 64 pixels (optional)
Supported telemetry systems PowerBox, Jeti, Futaba, Graupner, Multiplex
Dimensions 54 x 88 x 23 mm
Weight 77 g
Weight Sensor Switch 15 g
Temperature range -30°C to +85°C
4. SET CONTENTS
- PowerBox Source
- SensorSwitch
- 3 PowerPatch-leads (1x MPX / MPX and 2x MPX / JR)
- 4 rubber grommets and brass spacers
- 4 retaining screws
- Operating instructions in English and German