Operation Manual

Armadillo 9X Sweeper #4100033 Rev. D 07/15
© 2014-2015 Minuteman International, Inc.
Page 41
AUTOMATIC DIESEL SHUTOFF SWITCH
Only on the Diesel machines, this switch is an
automatic diesel shutdown that occurs if the oil
pressure is too low, below 5 psi (34 kPa), and/or the
water temperature is too high, above 200°F (93.3°C).
To start the engine, press and hold the switch while
turning the ignition switch. This will action will reset
and clear the error code. Auto shutdown will continue
if the oil pressure remains low or the water temperature
is to high.
LOW LP INDICATOR
The low LP indicator is an option on machines powered
by LP gas. The light is connected to a pressure valve
mounted in the LP lines. When the pressure gets low
in the LP tank (approximately 40 PSI) the indicator
light will illuminate red. The indicator light is located on
the operator dash area. When the light comes on the
machine has approximately ve minutes of running
time left. The operator should go to the refueling station
as soon as it is safely possible.