Portable Generator R N ep o ro t fo du r ct io n Operator’s Manual This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators). BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC MILWAUKEE, WISCONSIN, U.S.A. Manual No.
Thank you for purchasing this quality-built Briggs & Stratton® generator. We are pleased that you’ve placed your confidence in the PowerBoss® brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service. This manual contains safety information to make you aware of the hazards and risks associated with generators and how to avoid them.
Table of Contents Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Equipment Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Important Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Unpack Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operator Safety Safety Symbols and Meanings Equipment Description Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. The generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads. The generator’s revolving field is driven at about 3,600 rpm by a single-cylinder engine.
WARNING Fuel and its vapors are extremely flammable and explosive which could cause burns, fire or explosion resulting in death, serious injury and/or property damage. WHEN ADDING OR DRAINING FUEL • Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank. • Fill or drain fuel tank outdoors. • DO NOT overfill tank. Allow space for fuel expansion. • If fuel spills, wait until it evaporates before starting engine.
WARNING Generator voltage could cause electrical shock or burn resulting in death or serious injury. • DO NOT connect generator to a building’s electrical system. • DO NOT touch bare wires or receptacles. • DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged. • DO NOT operate generator in the rain or wet weather. • DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
Assembly Your generator is ready for use after it has been properly serviced with the recommended fuel and oil. If you have any problems with the assembly of your generator, please call the generator helpline at (800) 743-4115. If calling for assistance, please have the model, revision, and serial number from the identification label available. See Generator Features and Controls for identification label location. Unpack Generator 1. Set the carton on a rigid, flat surface. 2.
Grounding Fastener Generator Location The generator neutral is floating, which means that the AC stator winding is isolated from the grounding fastener and the AC receptacle ground pins. On a floating neutral generator the AC receptacle ground pins are not functional. Electrical devices, such as a GFCI, requiring a functioning AC receptacle ground pin will not operate.
Features and Controls Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. A M L K J B H C D E G N ep o ro t fo du r ct io n F R A - Fuel Tank — Capacity of two (2.0) U.S. gallons (7.6 l). B - On/Off Switch — Set this switch to on (I) before using recoil starter. Set switch to off (O) to switch off engine.
Cord Sets and Receptacles Use only high quality, well-insulated, grounded extension cords with the generator’s receptacles. Inspect extension cords before each use. Check the ratings of all extension cords before you use them. Extension cord sets used should be rated for AC loads 15 Amps or greater. Check operator’s manuals of devices to be powered for the manufacturer’s recommendations. Keep extension cords as short as possible to minimize voltage drop.
Operation Starting the Engine Disconnect all electrical loads from the generator. Use the following start instructions: 1. Make sure unit is on a level surface. NOTICE Failure to start and operate the unit on a level surface could cause the unit not to start or shut down during operation. 2. Move fuel shutoff lever (A) to on (I) position. B A C • DO NOT touch hot parts and AVOID hot exhaust gases. • Allow equipment to cool before touching. • Keep at least 5 feet (1.
Cold Weather Operation Under certain weather conditions (temperatures below 40°F [4°C] combined with high humidity), your generator may experience icing of the carburetor and/or the crankcase breather system. To reduce this problem, you need to perform the following: 1. Make sure generator has clean, fresh fuel. 2. Open fuel valve (turn valve to open position). 3. Use SAE 5W-30 oil. 4. Check oil level daily or after every eight (8) hours of operation. 5.
Don’t Overload Generator Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items. This is the amount of power your generator must produce to keep your items running. See Wattage Reference Guide. 3. Estimate how many surge (starting) watts you will need.
Maintenance Maintenance Schedule Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below. Emissions Control Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual. However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.
Oil NOTICE Overfilling with oil could cause the engine to not start, or hard starting. Oil Recommendations We recommend the use of Briggs & Stratton Warranty Certified oils for best performance. Other high-quality detergent oils are acceptable if classified for service SF, SG, SH, SJ or higher. DO NOT use special additives. Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected. • DO NOT overfill.
Service Air Cleaner Your engine will not run properly and may be damaged if you run it with a dirty air cleaner. Clean or replace more often if operating under dusty or dirty conditions. Inspect Muffler and Spark Arrester Inspect the muffler for cracks, corrosion, or other damage. Remove the spark arrester, if equipped, and inspect for damage or carbon blockage. If replacement parts are required, make sure to use only original equipment replacement parts. To service the air cleaner, follow these steps: 1.
Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined in Cleaning. • Check that cooling air slots and openings on generator are open and unobstructed. Other Storage Tips 1.
Troubleshooting Problem Cause Engine is running, but no AC output is available. Engine runs good at no-load but "bogs down" when loads are connected. 1. 2. 3. 4. Circuit breaker is open. Fault in generator. Poor connection or defective cord set. Connected device is bad. 1. 2. 3. 4. Reset circuit breaker. Contact authorized service facility. Check and repair. Connect another device that is in good condition. 1. 2. 3. 4. Short circuit in a connected load. Engine speed is too slow.
Warranties California, U.S. EPA, and Briggs & Stratton Corporation Emissions Control Warranty Statement N ep o ro t fo du r ct io n Your Warranty Rights And Obligations The California Air Resources Board, U.S. EPA, and Briggs & Stratton (B&S) are pleased to explain the emissions control system warranty on your Model Year 2011-2012 engine/equipment. In California, new small off-road engines and large spark ignited engines less than or equal to 1.
Look For Relevant Emissions Durability Period and Air Index Information On Your Small Off-Road Engine Emissions Label Engines that are certified to meet the California Air Resources Board (CARB) small off-road Emissions Standard must display information regarding the Emissions Durability Period and the Air Index. Briggs & Stratton makes this information available to the consumer on our emissions labels. The engine emissions label will indicate certification information.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY Effective November 1, 2009; replaces all undated Warranties and all Warranties dated before November 1, 2009. LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser.
Portable Generator Product Specifications N ep o ro t fo du r ct io n Starting Wattage . . . . . . . . . . . . . . . . . . . . . . . .2,000 Watts Wattage* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,700 Watts Load Current: at 120 Volts AC . . . . . . . . . . . . . . . . . . . . . . . .14.1 Amps Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single Phase Displacement . . . . . . . . . . . . .
Generador portátil R N ep o ro t fo du r ct io n Manual del Operario Este generador está clasificado conforme a la norma C22.2 No. 100-04 (motores y generadores) de la CSA (Canadian Standards Association [Asociación canadiense de normalización]). BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC MILWAUKEE, WISCONSIN, U.S.A.
Muchas gracias por comprar este generador Briggs & Stratton® de gran calidad. Nos alegra que haya depositado su confianza en la marca PowerBoss®. Siempre que sea utilizado de acuerdo con las instrucciones de este manual, su generador Briggs & Stratton le proporcionará muchos años de buen funcionamiento. Este manual contiene información sobre seguridad para hacerle consciente de los riesgos asociados a los generadores y mostrarle cómo evitarlos.
Tabla de Contenido Seguridad de operario . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Descripción del equipo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Información importante de seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Montaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Desembalaje del generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Seguridad de operario Símbolos sobre la seguridad y significados Descripción del equipo Lea atentamente este manual y familiarícese con el generador. Conozca sus aplicaciones, limitaciones y riesgos. Este generador funciona en base a un motor de campo eléctrico giratorio y de corriente alterna (CA). Fue diseñado con la finalidad de proveer energía eléctrica para lámparas eléctricas, aparatos, herramientas y cargas de motor compatibles. El campo giratorio del generador se mueve a unas 3.
ADVERTENCIA El combustible y sus vapores son extremadamente inflamables y explosivos, lo que podría provocar quemaduras, incendios o explosiones; así como daños materiales, lesiones graves o incluso la muerte. ADVERTENCIA PELIGRO DE GAS VENENOSO. Los gases del escape del motor contienen monóxido de carbono, un gas venenoso que podría matarlo en minutos. NO tiene olor, color ni sabor. Aun si no puede oler los vapores del escape, podría estar expuesto al gas de monóxido de carbono.
ADVERTENCIA Los gases y el calor de escape podrían inflamar los materiales combustibles y las estructuras o dañar el depósito de combustible y provocar incendios, así como daños materiales, lesiones graves o incluso la muerte. El contacto con la zona del silenciador podría producir quemaduras y lesiones graves. • NUNCA utilice la generador sin sus carcasas o tapas de protección. • NO utilice ropa suelta, joyas ni objetos que podrían quedar atrapados en el arrancador o en otras piezas rotativas.
Montaje Agregue combustible Su generador requiere de ciertos procedimientos de montaje y solo estará listo para ser utilizado después de haberle suministrado servicio con el combustible y aceite recomendados. Si usted tiene problemas con el montaje de su generador, por favor llame a la línea de ayuda para generadores al (800) 743-4115. Si llamar para la ayuda, tiene por favor el modelo, la revisión y el número de serie de etiqueta de identificación disponible.
3. Instale la tapa del tanque de combustible y la espera para algún combustible rociado para evaporar. Gran altitud En altitudes superiores a 1.524 metros (5.000 pies), se deberá utilizar gasolina con un mínimo de 85 octanos / 85 AKI (89 RON). Para seguir cumpliendo la normativa sobre emisiones, es necesario ajustar la unidad para su uso a gran altitud. De no realizarse este ajuste, el rendimiento se reducirá y el consumo de combustible y las emisiones aumentarán.
Controles y características Lea este Manual del Operario y reglas de seguridad antes de poner en marcha su generador. Compare las ilustraciones con su generador, para familiarizarse con la ubicación de los diversos controles y ajustes. Guarde este manual para futuras consultas. A M L K J B H C D E G N ep o ro t fo du r ct io n F A - Tanque del Combustible — El tanque tiene una capacidad de 2.0 galones americanos (7.6 l) de gasolina sin contenido de plomo.
Juegos de cordones y enchufes conectores Utilice exclusivamente cables prolongadores de alta calidad, bien aislados y con conexión a tierra para la toma doble de 120 V del generador. Examine los cables prolongadores antes de cada uso. Revise las capacidades de todos las cordones de extensión antes de usarlos. Los juegos de cordones de extensión utilizados deberán tener una capacidad de 125 Voltios AC a 15 Amperios o mayor para la mayoría de los dispositivos eléctricos.
Operando es correcto. La unidad puede equiparse con un dispositivo de protección de bajo nivel de aceite. En caso afirmativo, el nivel del aceite debe ser adecuado para que el motor arranque. Encienda el motor Desconecte todas las cargas eléctricas del generador. Use las siguientes instrucciones para encender: 1. Asegúrese de que la unidad está en una superficie plana.
3. Pulse el interruptor on/off a la posición off (O). ADVERTENCIA El combustible y sus vapores son extremadamente inflamables y explosivos, lo que podría provocar quemaduras, incendios o explosiones; así como daños materiales, lesiones graves o incluso la muerte. • NO coloque el estrangulador en la posición “Choke” (Estrangulamiento) para parar el motor. 4. Empuje la palanca de paso de combustible a la posición off (O).
AVISO Asegúrese de que la estructura de protección se pueda mover fácilmente para adaptarla a la dirección del viento. 2. NO encierre el generador más de lo que se muestra en la figura. La estructura de protección debe mantener una cantidad suficiente del calor disipado por el generador para evitar problemas de congelación. 3. Siga los pasos del 3 al 8 descritos en la sección Creación de una estructura de protección provisional para climas fríos.
Mantenimiento Plan de mantenimiento Siga los intervalos de horas o de calendario, los que sucedan antes. Si opera en condiciones adversas (señaladas más abajo) es necesario un mantenimiento más frecuente.
Aceite AVISO El llenado de aceite en exceso podría impedir el arranque del motor o provocar dificultades de arranque. Recomendaciones sobre el aceite Para obtener el mejor rendimiento, recomendamos utilizar aceites certificados con garantía Briggs & Stratton. También se pueden utilizar otros aceites detergentes de alta calidad con clasificación de servicio SF, SG, SH, SJ o superior. NO utilice aditivos especiales. Las temperaturas exteriores determinan la viscosidad adecuada del aceite para el motor.
Servicio del filtro de aire Si se utiliza con un filtro de aire sucio, el motor no funcionará correctamente y puede sufrir daños. Haga cambios más frecuentes si trabaja en zonas sucias o donde hay polvo. Para dar servicio al filtro de aire, siga estos pasos: 1. Afloje el pasador (A) que sujeta la tapa (B) y retire la tapa.
Ajuste del carburador El carburador de este motor es de baja emisión. Está equipado con una válvula de mezcla de ralentí no ajustable y, en algunos casos, con ralentí regulado. Los niveles de ralentí regulado y velocidad máxima se ajustan en la fábrica. Si es necesario modificarlos, acuda a un distribuidor de servicio. PRECAUCIÓN Las velocidades de funcionamiento excesivamente altas podrían provocar lesiones leves y/o daños al generador. Las velocidades excesivamente bajas incrementan la carga de trabajo.
Resolución de problemas Problemo El motor está funcionando pero no existe salida de AC disponsible. Causa 1. El interruptor automático de circuito está abierto. 2. Conexión mal o defectuosa del juego de cables. 3. El dispositivo conectado está dañado. 4. Avería en el generador. El motor funciona bien sin carga pero "funciona mal" cuando se le contectan cargas. 18 3. Conecte otro dispositivo que esté buenas condiciones. 4. Contacte el distribuidor de servicio autorizado. 1.
Garantías Garantía de control de emisiones de California, U.S. EPA y Briggs & Stratton Corporation N ep o ro t fo du r ct io n Derechos y obligaciones de la garantía California Air Resources Board, U.S. EPA y Briggs & Stratton (B&S) le explican a continuación la garantía del sistema de control de emisiones de su motor/equipo modelo 2011-2012.
B&S. B&S no será responsable de la cobertura de la garantía de fallos de componentes relacionados con el sistema de emisiones cubiertos por la garantía provocados por el uso de componentes complementarios o modificados.
POLÍTICA DE GARANTÍA PARA EL PROPIETARIO DE GENERADOR PORTÁTIL BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC Fecha de entrada en vigor: 1 de noviembre de 2009; sustituye a todas las garantías sin fecha y a las de fecha anterior al 1 de noviembre de 2009. GARANTÍA LIMITADA Briggs & Stratton Power Products Group, LLC reparará o sustituirá sin cargo alguno cualquier componente del generador portátil que presente defectos de materiales y/o mano de obra.
Generador Portátil Especificaciones del producto N ep o ro t fo du r ct io n Vataje que Empieza . . . . . . . . . . . . . . . . .2,000 Vatios (2,0 kW) Vataje* . . . . . . . . . . . . . . . . . . . . . . . . . . .1,700 vatios (1,7 kW) Corriente Carga: a 120 Voltios de C.A. . . . . . . . . . . . . . . . . . . . .14,1 Amperios Frecuencia Nominal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Hz Fase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .