Owner's Manual

18
Authorized Service Agency Section
Pump does not work
Look For Correction
1
No water in sink Fill sink with water
2
LIQUID LEVEL SENSOR dirty Clean LIQUID LEVEL SENSOR
3
No incoming power to unit Reset customer’s breaker in breaker control panel
4
Blown fuses Replace blown fuse – Refer to wiring diagram for correct fuses
5
Loose wires Tighten wires
6
LIQUID LEVEL CONTROL setting is too low See page 20
7
Defective LIQUID LEVEL CONTROL or SOCKET
Check and replace as necessary
8
Tripped OVERLOAD Push red RESET bar on OVERLOAD
9
Defective START or STOP switch Check and replace as necessary
10
TIMER settings incorrect Check – See page 21
11
Defective TIMER Check and replace as necessary
12
Defective CONTACTOR/OVERLOAD Check and replace as necessary
13
Defective PUMP MOTOR Check and replace as necessary
Overload trips
Look For Correction
1 Low voltage to unit Check with Volt meter while running
2 Improper Setting on Overload Set on “10”
3 Debris in PUMP intake Clean
4 Debris in IMPELLER Remove PUMP and clean
5 Defective CONTACTOR Check and replace as necessary
6 Defective OVERLOAD Check and replace as necessary
7 Defective PUMP MOTOR If amp draw is greater than 10% of motor rating and
all of above check
out, then replace MOTOR
Intermittent running
Look For Correction
1
See 2, 5, 6, 7, 9, 10, 11 under Pump does not work
2
Overload Tripping and Resetting See “Overload Trips”
3
Sink not filled to “Water Line” Make sure sink is filled to “Water Line”. Soap foam does not
count.