Wash Pump/Heater Will not Operate
Refer to the previous checklist under the “Facility
Owner / Manager Section” before proceeding to the
following checklist items:
Verify that LED #1 (Power On) is illuminated. If LED #1 is not illuminated,
check:
Main power connection and wiring
Fuse inside the control enclosure
Bi-metallic disc switch for water temperature (switch must be closed
if water temperature is below 120°F)
Bi-metallic disc switch for motor temperature (switch must be
closed if motor temperature is below 15F)
Check to see that the Liquid Level LEDs #3 and #4 are illuminated when
the wash tank is filled to the waterline.
If either one or both of the lights are not illuminated:
Clean the liquid level sensors as described in the “Preventive
Maintenance” section of this manual.
Be sure that all connections to and from the liquid level sensors are
secure and that there is no physical damage to the wiring.
If damage to connectors and/or wiring is found, contact Power Soak
Systems, Inc. at 800-444-9624.
If the above troubleshooting guidelines do not correct the problem, it will be
necessary to contact Power Soak Systems, Inc. at 1-800-444-9624.