Owner's Manual Owner manual
31
•
A wiring diagram is located in the machine’s control panel
enclosure.
Specific part numbers and part information can be obtained from the
factory by calling 800-444-9624. Service information is also found on
the Power Soak web site (http://powersoak.com) under the SUPPORT
tab.
Plumbing Requirements
The PS-275 requires the following plumbing connections:
•
One 3/4” (19mm) or 1/2” (12 mm) cold water supply line.
•
One 3/4” (19mm) or 1/2” (12 mm) hot water supply line.
•
One 3” (75mm) connection is recommenced for an in-floor main line.
•
One waste water connection minimum 1-½” (38mm).
Note: Each tank will have a rear drain exit 1-½” (38mm) female
threaded connection that will have to be connected to the waste water
connection. Drain connection must not exceed elevations higher than
10-1/2 inches above the floor where the Power Soak machine is
located.