INSTALLATION MANUAL Owner manual

3
Plumbing Requirements
The plumbing required for your system depends on the type of system you have
purchased:
Mobile units must have a floor sink nearby that they can be moved to for
emptying waste water. In addition, some mobile units are equipped with
faucets that will require a temperature regulated 1/2 NPT potable water
flexible connection.
Free-standing stationary units and built-in units must have their drains
permanently connected to the building scullery sewer system. In addition,
these units are equipped with faucets that will require a temperature
regulated 1/2 NPT potable water connection.
Mechanical Installation of Built-in Units
Both the Drop-in and the Weld-in versions of the Power Soak Silverware Pre-
washing System are designed to be installed in existing dish tables. Installation of
both types is very similar with the main difference being that the Drop-in version
requires no field welding.
Drop-in Version Installation
Review the drawings that came with the unit to confirm that the location chosen for
the system is adequate with respect to:
Drain proximity
Electrical power proximity
Adequate space on the dish table top for the tank and the faucet
Appropriate location for the control box bracket
Absence of ribs or other features on the underside of the selected dish table
location