Owner's Manual Owner manual

20
Wash Pump Will Not Operate
Refer to the previous checklist under the “Facility
Owner / Manager Section” before proceeding to the
following checklist items:
LOOK FOR CORRECTION
1 No water in sink Fill sink with water
2 LIQUID LEVEL SENSOR dirty Clean LIQUID LEVEL SENSOR
3 No incoming power to unit
Reset customer's breaker in
breaker control panel
4 Loose wires Tighten wires
5 LIQUID LEVEL SENSOR setting is too low See page 21
6 Defective LIQUID LEVEL CONTROL Checek and replace as necessary
Overload trips
LOOK FOR CORRECTION
1 Low voltage to unit Check with Volt meter whie running
2 Debris in PUMP intake Clean
3 Debris in IMPELLER Remove PUMP and clean
4 Defective CONTACTOR Check and replace as necessary
5 Defective OVERLOAD Check and replace as necessary
6 Defective PUMP MOTOR
If the above troubleshooting guidelines do not correct the problem, contact
Power Soak Systems at (816)222-2400.