Installation Instructions for Kay Chemical / Power Soak Dual Dispenser Pump (01/02/03)
Step #1 Verify that the male and female multi-pin connectors of the wiring harness, between the two halves of the unit, are tightened and secure. Multi-pin connector behind unit Step #2 Locate the multi-pin connector that is underneath the clean drain board (behind the dual dispenser pump) and secure it to the back of the dispenser.
Installation of the Pump Feed and Discharge Tubes Step #1 Run a piece of “clear” plastic tubing (the Feed Tube), provided with the installation kit, from the detergent bag holder to the dispenser pump. If necessary, use the support loops located under the unit’s sinks to hang the tubing. Cut the detergent Feed Tube to the proper length and connect it to the barbed fitting on the left, “Wash Detergent”, pump.
Step #5 Place a bag of Liquid Storm detergent into the bag holder. Locate the detergent connector fitting, fasten it to the Feed Tube then connect the fitting to the bag of Liquid Storm. Warning: Refer to, and follow, all specific handling instructions provided by the chemical manufacturer. Instructions, labels and MSDS sheets should be supplied with the detergent. Step #6 Connect the Feed Tube from the Sanitizer pump to the Kayquat sanitizer supply.
Pump Timer Settings for Wash Tank (Liquid Storm), cont’d To determine the correct timer setting, measure the depth of the Power Soak unit (from the front edge to the back edge). Then, measure the Wash Tank from the left side to the right side. Use the following information to set the DIP switches on the timer: 34" deep unit - Liquid Storm Timer Settings for PS-200 Wash Tank Tank Tank Liquid Pump DIP Switch Settings Length Volume Storm Time (ON) (inches) (gallons) (ounces) (seconds) 30 59.7 5.
Pump Timer Settings for Sanitizer Tank (Kayquat) Open the dual dispenser pump enclosure and locate the correct timer for the Kayquat (sanitizer) dispenser pump. The correct timer is mounted on the right-hand side of the door. The DIP switches on the timer represent a specific number of seconds. Set any combination of the switches to “ON” in order to obtain the proper amount of pump run time.
Priming the Feed and Discharge Lines After both pump timers have been set, close and lock the door to the dispenser enclosure and locate the “prime” buttons for the Wash Detergent and Sanitizer pumps. The prime buttons are located under the enclosure on the left-hand side (Detergent) and right-hand side (Sanitizer). Press and hold the left prime button until the Detergent flows from the Wash Tank injector nozzle.
13910 Kessler Drive Grandview, MO 64030 Office: 816-761-3250 Fax: 816-761-0544 www.powersoak.