User guide

EMA Linear Actuator
Tel: +44 (0) 1358 285100 email: sales@powerjacks.com
web: www.powerjacks.com
14
7.5.2 Single Phase Motor Connections
This diagram is typical for motors with on board capacitors connected to the motor for
the correct start and run characteristics. For motors with loose capacitors consult Power
Jacks or the motor manufacturer.
7.5.3 DC Motor
8. Maintenance and Lubrication
Unless otherwise specified the actuators are shipped with their full requirement of
grease for normal operation. The actuators should not need a lubrication refill within their
standard life provided they have been installed and used correctly. Should the unit
require lubrication then use one of the following extreme pressure greases or their
equivalent:
Shell Alvania WR2
BP Energrease LC2
Castrol Spheerol L-EP2
Mobil Mobilux EP2
If ambient temperatures exceed 50°C (122°F) consult Power Jacks.
L1
L2
L1
L2
L1
L1
L2
L2
Forward
Reverse
Motor
+ve
-ve