Datasheet
17
TNY274-280
F
4/06
Parameter Symbol
Conditions
SOURCE = 0 V; T
J
= -40 to 125 °C
See Figure 16
(Unless Otherwise Specified)
Min Typ Max Units
OUTPUT (cont.)
ON-State
Resistance
R
DS(ON)
TNY277
I
D
= 45 mA
T
J
= 25 °C 7.8 9.0
Ω
T
J
= 100 °C 11.7 13.5
TNY278
I
D
= 55 mA
T
J
= 25 °C 5.2 6.0
T
J
= 100 °C 7.8 9.0
TNY279
I
D
= 65 mA
T
J
= 25 °C 3.9 4.5
T
J
= 100 °C 5.8 6.7
TNY280
I
D
= 75 mA
T
J
= 25 °C 2.6 3.0
T
J
= 100 °C 3.9 4.5
OFF-State Drain
Leakage Current
I
DSS1
V
BP/M
= 6.2 V
V
EN/UV
= 0 V
V
DS
= 560 V
T
J
= 125 °C
See Note I
TNY274-276 50
µATNY277-278 100
TNY279-280 200
I
DSS2
V
BP/M
= 6.2 V
V
EN/UV
= 0 V
V
DS
= 375 V,
T
J
= 50 °C
See Note G, I
15
Breakdown
Voltage
BV
DSS
V
BP
= 6.2 V, V
EN/UV
= 0 V,
See Note J, T
J
= 25 °C
700 V
DRAIN Supply
Voltage
50 V
Auto-Restart
ON-Time at f
OSC
t
AR
T
J
= 25 °C
See Note K
64 ms
Auto-Restart
Duty Cycle
DC
AR
T
J
= 25 °C 3 %