DISCHARGING THE CAPACITOR:
Never remove the capacitor without discharging the stored power – it can give a
dangerous electrical shock!
To disconnect the capacitor, follow these instructions:
1. Disconnect the cables from the capacitor in the following order:
a) positive (+) cable
b) ground (-) cable
2. Holding the resistor provided, touch the leads to the positive (+) and ground (-)
terminals of the capacitor. After
1~5 minutes, the capacitor will be discharged (The
charging resistor will become hot!) Then you can safely remove and handle it.
WARNING!!
THIS POWER CAPACITOR MAY EXPLODE AND CAUSE SERIOUS INJURY IF ABUSED
OR CONNECTED IMPROPERLY. PLEASE REFER TO THE INSTRUCTIONS CONTAINED
IN THIS MANUAL FOR CORRECT OUNTING, CHARGING/DISCHARGING AND WIRING