EVD-1 • 5401043 • REV M • 9/07 WARRANTY INFORMATION The essential purpose of any sale or contract for sale of any of the products listed in the POTTER catalog or price list is the furnishing of that product. It is expressly understood that in furnishing said product, POTTER does not agree to insure the Purchaser against any losses the Purchaser may incur, even if resulting from the malfunction of said product.
EVD-1 • 5401043 • REV M • 9/07 CONTENTS General Information Features Specifications Ordering Information EVD-1 Controller Accumulator Function EVD-1 Controller Details EVD-1 Terminal Connections Recommended Wiring Recommended Wire Types Recommended Wiring EVD-1 Controller Recommended Control Panel Wiring and RTA Connections Installation EVD Wiring with Safe Detector Zone and 24 Hour Alarm Zone EVD Wiring with Safe Detector Zone Only Sensitivity Adjustments Analog Test Point Levels Testing Safe Construction
EVD-1 • 5401043 • REV M • 9/07 4
EVD-1 • 5401043 • REV M • 9/07 General Information The EVD-1, Electronic Vibration Detector, is listed by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada for primary protection of Mercantile or Bank, safe or vault and supplementary protection of interior units such as file cabinets, display cases, walls and ceilings. The detector must be used with an appropriate UL listed control unit.
EVD-1 • 5401043 • REV M • 9/07 If the main burglar panel has ground fault detection circuitry, it may be necessary to power the EVD from a separate power supply, not from the auxiliary power on the burglar panel. Alternately, the safe may be insulated from ground. EVD-1 Controller The EVD-1 controller is a microprocessor controlled, vibration detector that incorporates advanced detection methods for identifying all common types of attacks.
EVD-1 • 5401043 • REV M • 9/07 EVD-1 Terminal Connections Terminal Terminal Description No.
EVD-1 • 5401043 • REV M • 9/07 Figure 2 Recommended Wiring EVD-1 Controller EVD-1 8 1 2 EVD-1 7 8 3 2 1 4 5 9 2 6 2 (a) (b) Recommended Control Panel Wiring and Remote Test and Annunciator Connections Figure 3a MODEL EVD-1 CONTROL UNIT END OF LINE RESISTORS 12 VOLT DC SUPPLY BLACK RED - RED ALARM LED + DRAIN WIRE FOR INNER SHIELD HIGH SECURITY CABLE CURRENT LIMITING RESISTOR TEST SWITCH YELLOW TAMPER LED DRAIN WIRE FOR OUTER SHIELD + MODEL RTA - 24 HOUR ALARM ZONE SAFE DET
EVD-1 • 5401043 • REV M • 9/07 Recommended Control Panel Wiring With Safe Detector Zone And 24 Hour Alarm (High Security "B" Cable Required For UL Safe Complete Installations) Figure 3b DWG# 1043-10 9
EVD-1 • 5401043 • REV M • 9/07 Optional Control Panel Wiring With Safe Detector Zone Only (4 Conductor Shielded Cable Required) Figure 3c 10
EVD-1 • 5401043 • REV M • 9/07 Sensitivity Adjustments 1. 2. 3. Adjust the EVD-1’s internal pickup sensitivity control, RV1, to 1/2 scale (12 o’clock position). Refer to Figure 1 for location of RV1. Adjust accumulator rotary switch, S1, to desired setting. A setting of zero disables the accumulator function. Refer to Figure 1 for location of S1. Perform simulated attack tests on all accessible surfaces that are protected by EVD-1.
EVD-1 • 5401043 • REV M • 9/07 Recommended Detector Locations Single Detector Applications All safe applications must have at least one EVD-1 on the body of the safe. When only one detector is required on a safe, mount the detector on the exterior of the safe on the door hinge side, near the front edge and centered within the height of the safe. (Ideally, mount the detector’s sensor center point 2 inches in from the front edge of the safe on the centerline of the safe’s height, refer to Figure 9).
EVD-1 • 5401043 • REV M • 9/07 Table 4. Max.
EVD-1 • 5401043 • REV M • 9/07 Table 6 Recommended Safe Sizes When Mounting Detector on the Safe Door Recommended Detector Locations Detector on safe door: If necessary, the detector can be mounted on the safe door (single door only). Mount the detector 1.75" from the edge of the hinge side of the door, centered on equal distance between both hinges. Fig. 9 shows the recommended detector location when mounting the detector on the door.
EVD-1 • 5401043 • REV M • 9/07 Figure 8 Typical Wall Protection Installation Figure 9 Dimensions All dimensions in inches DETECTOR RANGE DETECTOR SPACING DETECTOR SPACING RECTANGULAR AREA OF 100% COVERAGE CIRCULAR AREA OF 100% COVERAGE Table 7 Recommended Maximum EVD-1 Spacing for Wall Protection Material Sensitivity Setting Detector Range Rectangular Area of 100% Coverage Steel plates at least 1/4" thick Minimum 8.0' 11.3' x 11.3' 8' x 13.9' 10' x 12.5' 15' x 5.6' - Half 15.0' 21.