SDS

Post Proservative
Safety Data Sheet
DATE OF ISSUE: Feb 17 2023
Page 1 of 7
SECTION 1: Chemical Product and Company Identification
Trade name (as labeled): Cobra
TM
Rod
Product Class: ..................................... Fungicide/Wood Preservative
Product description: .......................... Fungicide in the form of solid fused glass rod; used to prevent decay
in wood structures by inserting into pre-drilled holes.
PCP Registration No.: .......................... 25580
EPA Registration No.: .......................... 71653-2
Manufacturer’s Name: ......................... GENICS
27717 Acheson Rd.
Acheson Industrial Park.
Acheson
Alberta Canada
T7X 5A7
Emergency Phone: ........................................ For Hazardous Materials [or Dangerous Goods] Incident Spill, Leak, Fire,
Exposure, or Accident
Call CHEMTREC Day or Night 1-800-424-9300 / +1 703-527-3887
Genics Business Phone: ...................... (780) 962-1000
SECTION 2: Hazard Identification (toxicological properties)
EMERGENCY OVERVIEW
Harmful if swallowed. Avoid contact with eyes and skin. Avoid rubbing eyes while working with product. Avoid
breathing dust, use only in well ventilated area.
Cobra
TM
Rods are a dark green, solid, glass-like substance that are not flammable, combustible, or explosive
and have low acute oral and zero dermal irritation. Cobra
TM
Rods are not intended for ingestion. Cobra
TM
Rods
have low acute toxicity and small amounts accidentally swallowed are not likely to cause effects. Some rods
may have sharp edges and in cases where they are completely swallowed these sharp edges may cause
grazing of the intestinal tract.
Name Toxicological Data
Cobra Rod LD50 oral rat >3500 mg/kg B.W.
SYMPTOMS OF OVEREXPOSURE BY ROUTE OF EXPOSURE: There is no health hazard
anticipated to occur during routine use of this product. The symptoms of such overexposures are
described in the following paragraphs.
INHALATION: Though unlikely to occur, a minor hazard may exist via inhalation of particulates
generated by the product. At most, the exposure to the dust causes mild irritation of the respiratory
system, or mucous membranes. Symptoms may include redness itching, or coughing.
CONTACT WITH SKIN OR EYES: Though unlikely to occur, contact with dusts generated by this
product and the skin or eyes may lead to mild irritation.
SKIN ABSORPTION: Exposure via skin absorption will not occur with product.
INGESTION: Though very unlikely to occur in an occupational setting, if this product is ingested,
symptoms may include nausea and vomiting.
INJECTION: Injection of this product (via punctures with contaminated, sharp objects or pre-existing
breaks in the skin) can produce redness, local swelling, and tissue damage at the injection site.

Summary of content (7 pages)