3.6.1.7. Pixel Clock Frequency p3i_CL and p3i_CL/PMC
Table 3.21. Maximum Pixel Clock Frequency
Parameter Description Min Typ Max Unit
Clock-f for Mode0(1x8 bit), Mode1(2x8
bit), Mode4(1x10 bit),
Mode6(1x12 bit), Mode8(1x14
bit), Mode9(1x16 bit)
66 MHz
Clock-f for Mode2(3x8 bit), Mode3(3x8
bit RGB), Mode5(2x10 bit),
Mode7(2x12 bit)
38 MHz
3.6.2. Environmental Conditions
Table 3.22. Environmental Conditions
Storage Temperature: -20° C - 70° C
Operating Temperature: 0° C - 45°C (2 m/s forced air cooling)
Maximum Operating Humidity: 85 % relative
Chapter 3. Hardware Reference