el_SetRegister(wBoardId,"Gain1", 1, 1); // set Gain1 to 1
el_SetRegister(wBoardId,"Gain1", 0, 1); // set Gain1 to 0
A.9. JAI CV-M2 Ikegami SKC-145T2 Basler A102k
These cameras have been adapted in a free running and an triggered mode. The triggered mode is
intended to be used with pulse width mode controlled exposure. Exposure time determined by the camera
is also possible, but el_SetExposureTime() has still to be used, because the valued is needed to calculate
allowed valued for the cycle time.
An exception are the partial modes where no limit for the cycle time is enforced because it depends on
the setting of the camera. These modes are only intended for the experienced user because wrong cycle
times can lead to unpredictable results. For this reason no support for these modes can be given.
Appendix A. Cameras
93