TP-6000 SERIES USER’S MANUAL TOUCH PANEL POS SYSTEM Rev.
SOME IMPORTANT NOTES FCC NOTES This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested and found to comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against interference when operated in a commercial environment.
TABLE OF CONTENTS BRIEF INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 THE USER’S MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 THE PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 Available Models . ............
PREPARING THE MAIN UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 4 JOINING MAIN UNIT AND PADDLE . . . . . . . . . . . . . . . . . . . . . 4 - 4 OPENING CABLE COVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 5 CONNECTING CABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 6 INSTALLING CASH DRAWERS . . . . . . . . . . . . . . . . . . . . . . . . 4 - 6 WALL MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BRIEF INTRODUCTION THE USER’S MANUAL The purpose of this manual is to guide the user in the initial installation and general use of the Posiflex fully integrated compact touch terminal system with touch panel input. TP6000 series is a product group of fully integrated PC based touch terminal systems. However, this manual does not intend to explain any application program that may be supplied with the TP6000 systems.
STANDARD FEATURES a) CPU: Celeron 366MHz up to 500 MHz HDD: 6.4 GB or above b) Support MS DOS, WIN98, WIN NT, WIN 2000 environment (WIN 2000 support starting June 2000) c) Power saving support: doze or suspension mode d) High quality 12.1” / 15.
o) Built-in UPS function to support the system from intermittent power failure (battery itself is an option) p) Accidental power off protection – The power switch is safely located at one side, and this power switch can be defined as a “ON” switch only through software command q) Forced power off against system malfunction under the power switch on/off mode r) Touch control functions: left/right button, double click, drag & draw s) Touch sound can be enabled/disabled or pitch adjusted by software control
TP6000 USER’S MANUAL 1 - 4
SYSTEM BOX CONTENTS MAIN UNIT & PADDLE ASSEMBLY Open the carton User’s Manual Carton Packaging materials Packaging materials Power Supply Unit Documents for Preloaded OS Power Cord Bottom of TP6000 System and take all the contents out together with the packaging materials. Take out the accessories/options from the partitions in the packaging materials and unfold the packaging materials carefully to unload the upsidedown loaded TP6000 series touch terminal.
The COM1 terminator will be already mounted on the system unit when being shipped. The latch key for cable cover lock will be in a bag. OPTIONAL DEVICES There are several options that will be mounted on/in the main system unit either by the manufacturer if ordered. These optional devices include: • DRAM expansion – This option includes any possibility from basic 32 MB to maximum 1 GB. • Built in card reader – This option will be on the right edge when installed.
PARTS IDENTIFICATION FRONT VIEW MSR Unit Display Screen + Touch Panel Main Unit Adjustable Paddle Assembly The MSR unit is option to both 12” and 15” models. The LED in the logo area serves for multiple purposes through giving different indication of steady/flashing green/orange light. Please refer to the paragraph discussing the LED indication in the chapter of “USING THE TOUCH POS” of this manual.
SIDE VIEWS Right Side View Latch Hole For Cable Cover Push In This Direction To Adjust The Tilt Angle Of The Display Panel Lock/Release Lever Left Side View Push Down To Switch The Power ON/OFF Latch Hole For Cable Cover Slide Switch For Power On/Off Control TP6000 USER’S MANUAL 3 - 2
REAR VIEW Lock/Release Button To Detach The Main Unit Optional MSR Unit Lock/Release Lever Cable Exit REAR VIEW OF MAIN UNIT Service Window Matching Pegs Cable Exit Cable Cover Removal Hollow Of Cable Cover TP6000 USER’S MANUAL 3 - 3
ADJUSTABLE PADDLE ASSEMBLY Matching Holes Paddle Base Lock/Release Lever BOTTOM OF PADDLE ASSEMBLY Base UPS Battery Cover Cable Passage Cover Lock/Release Button For Main Unit Cable Exit Paddle CONNECTORS Turn Counterclockwise Then Take Out The Latch Key TP6000 USER’S MANUAL 3 - 4 Pull The Cable Cover Out In This Direction
USB5 Port PS/2 KB PS/2 Mouse COM1 Port Cash Drawer Controller COM2 Port External VGA Port Power Input Jack UPS Battery Connector LPT1 Printer Port External FDD Port LED Connector USB4 Port USB3 Port USB2 Port USB1 Port LAN Port MSR Port TP6000 USER’S MANUAL 3 - 5
TP6000 USER’S MANUAL 3 - 6
INSTALLATION GUIDES CAUTION: Before any installation or cable connection to the set, please always make certain that the system is turned off and the external power source to the set is removed to prevent electric hazard! Never touch any metal pin in the connectors or circuits to avoid high voltage hazard or electrostatic discharge damage unless the operator is well grounded. SEPARATING MAIN UNIT Press the Lock/Release button and lift the main unit to detach it from the paddle assembly.
PREPARING PADDLE ASSEMBLY Take the adjustable paddle assembly and turn it up side down to show the bottom of the base. 2 Sets of 4 Matching Holes Screws Cable Passage Cover Adjustable Paddle Now, unscrew the 2 screws on the cable passage cover and take the cable Lock/Release passage cover away to show the cable Lever passage.
INSTALLING UPS BATTERY UPS Battery Removed Battery Cover Place the optional UPS battery in the battery compartment in the way as indicated in the picture. Screw on the battery cover and join the battery cable into the cable routing operation. Please enable UPS function in software setting before use. ROUTING THE CABLES Place all the cables required for connections to the TP6000 series except those for special application purposes into the cable passage.
PREPARING THE MAIN UNIT On the back of the main unit, there are 4 matching pegs and a service window. Push open the service window in the direction as indicated in the picture, one can find a button cell battery socket, a 1 x 3 header (JP10) with 1 jumper and a 2 x 3 header (JP8) with 2 jumpers. Service Window Push Open To The Right 4 Matching Pegs This battery socket accepts a 3 V button cell Lithium battery (CR2032) required to support the system real time clock.
the hole and make sure that all pegs are inside the holes. Then slide the main unit down to move the pegs into the lower slot part of the holes till it clicks. Note that all the cables come out of the paddle from the lower edge and won’t get trapped by this mounting operation. If later on you want to remove the main unit from the paddle, you’ll have to press down the lock/release button on back of the paddle at the time lifting the main unit.
CONNECTING CABLES Connect the cables required to the appropriate connectors. Please make sure that each connector has to be connected to the right port in the right orientation. Some connectors have to be inserted till a click is heard such as the LAN connector, the external FDD connector, the power connector and the cash drawer connector. It is recommended to screw on the connector once it is inserted such as the external VGA connector, the LPT port connector and the COM port connectors.
the shorter one for the original cash drawer “CR1” and use the longer one for the extended cash drawer “CR2” that will be distinguished by the software command. In this way, the TP6000 is capable of controlling two cash drawers independently through software command. WALL MOUNTING The major part in the wall mounting kit is a bracket as shown in the picture.
either 360 mm or 380 mm depending on the position adjusted. When the main unit is tilted to near horizontal position, the total height required is 275 mm.
USING THE TOUCH POS APPLICATION ENVIRONMENT It is very important that you check the following operational guidelines: Ventilation This terminal must NOT be operated in an environment with restricted ventilation. The installation should be such that there is at least 25mm air clearance around any top or side ventilation holes. The installation must also be such that there is a free flow of air around the unit at ALL times.
Parallel printer – connect to Parallel port Serial printer – use USB to RS232 adapter to connect to USB port or directly connect to COM1 port Serial barcode scanner – use IW-2000PS2 (RS232 to KB wedge converter) to connect to PS2 KB port Cash drawer – connect to CR port Serial Weight scaler – use IW-2000PS2 (RS232 to KB wedge converter) to connect to PS2 KB port Mouse – use PS2 mouse or USB mouse KB – use PS2 KB or USB KB Touch panel controller – please select the standard PS2 int
POWER ON/OFF LED Indicator There is an LED in the logo area that serves for multiple purposes. When the TP6000 is standing by for powering up in the presence of external power supply, the LED is orange. When the TP6000 is powered up and working normally with the external power supply, the LED is green. When the external power extinguishes and the TP6000 is working on the optional UPS battery power, the green LED flashes.
Hardware Switch The power switch located at left side of the main unit is a slide type switch. This switch controls the power on/off of the system. This switch turns the system on when slid downward at original power connection status or power off status. The switch will always spring back to its original position when external force is removed. This switch turns the system off when slid downward again at power on status.
program shall prepare the terminal to standby for LAN Wake Up during power off so that when the predefined condition is met (LAN status change or receiving certain packet) the TP6000 will be powered on. When the TP6000 system is turned off after a successful boot up, the defined preset power on functions will keep monitoring for the preset conditions.
DISPLAY RESOLUTION For best viewing result please set your display resolution of TP6012 at 800 x 600 with true color in the operation system. For TP6015, please set the display resolution at 1024 x 768 with high color. TOUCH PANEL The touch panel in TP6000 series, either PS2 interfaced or RS232 interfaced, when its driver is properly installed, works exactly like a standard mouse.
also be obtained through downloading from our web site. Application of this program provides control over the MSR, the touch panel and the power control of the Posiflex Touch Terminal. For an RS232 interfaced touch panel, the touch panel part of the following description should be disregarded and please refer to the paragraph “RS232 TOUCH MONITOR MOUSE” instead.
If, for any reason, the user wants to remove the driver for the RS232 touch controller, please select “Monitor Mouse for Windows 95” in the program list for removal.