User manual
Poseidon MKVI User Manual
Appendix 2
Routing the inator hoses
Connect the the O
2
inator hose “marked O
2
” to your onboard O
2
gas supply (or any other
offboard source). Route the hose over your right shoulder and connect to the O
2
inator valve
though the quick connection.
Connect the the diluent inator hose to your onboard diluent gas supply (or any other offboard
source). Route the hose over your left sholder and connet to the diluent inator valve though
the quick connection.
The valves described above can be supplied with any other gas supply. E.g. your onboard
oxygen is empty but you have a bailout stage with oxygen or another gas that you would like
to manually add to the loop.
WARNING:
Gas plugged in to the system needs to be selected carefully to
avoid hazardous loop PO
2
.
Figure A2-6. LP hose routing.
Page 84