User manual

Poseidon MKVI User Manual Appendix 1
Page 75
T# Time (sec) Description Error Code Solution
29
31
35
30
34
38
Audio Alarm Speaker. This test measures the amount of elec-
trical current consumed by the speaker in the battery (Audio
Alarm), when activated.
Diluent Cylinder Pressure Sensor Validation. This test includes
a series of tests that conrm that power can be supplied to the
diluent cylinder pressure sensor, and that the signal from the
sensor is within limits (regardless of whether the cylinder valve
is turned on).
Secondary Oxygen Sensor Validation. This test measures the
voltage output from the secondary oxygen sensor, to ensure it
exceeds a minimum threshold value. Although it is possible
that the gas mixture in the breathing loop is hypoxic, a failure
of this test more likely indicates a failed oxygen sensor and / or
a broken wire. This test does not ensure proper function of the
sensor (veried during the calibration routine, t53).
Oxygen Cylinder Pressure Sensor Validation. This test includes
a series of tests that conrm that power can be supplied to the
oxygen cylinder pressure sensor, and that the signal from the
sensor is within limits (regardless of whether the cylinder valve
is turned on).
Primary Oxygen Sensor Validation. This test measures the
voltage output from the primary oxygen sensor, to ensure it
exceeds a minimum threshold value. Although it is possible
that the gas mixture in the breathing loop is hypoxic, a failure
of this test more likely indicates a failed oxygen sensor and / or
a broken wire. This test does not ensure proper function of the
sensor (veried during the calibration routine, t53).
Depth/Temperature Sensor Validation. This test ensures that
the temperature sensor embedded in the depth sensor is
working correctly.
4,5
7,5
2
7,5
2
2
11=Current
too low
12=Current
too high
17=Locked on
18=Locked off
19=Defective
26=Voltage
low
27=Voltage
very low
31=Sensor
Suspect
14=Locked on
15=Locked off
16=Defective
26=Voltage
low
27=Voltage
very low
1) Standard Response; 2) If test failure persists, or the Audio Alarm speaker
does not sound during this test, contact an authorized Poseidon Service
Center for repair.
1) Standard Response; 2) If test failure persists, contact an authorized
Poseidon Service Center for repair.
1) Inspect the secondary oxygen sensor, the wires leading from it, and the
electrical contacts at the back of the sensor cavity, and replace the sensor
and/or wires if either are suspect; 2) Standard Response; 3) If test failure
persists, contact an authorized Poseidon Service Center for repair.
1) Standard Response; 2) If test failure persists, contact an authorized
Poseidon Service Center for repair.
1) Inspect the primary oxygen sensor, the wires leading from it, and the
electrical contacts at the back of the sensor cavity, and replace the sensor
and/or wires if either are suspect; 2) Standard Response; 3) If test failure
persists, contact an authorized Poseidon Service Center for repair.
1) Standard Response; 2) If test continues to fail, ensure loop temperature
is within limits; 3) If test failure persists, contact an authorized Poseidon
Service Center for repair.