Poseidon MKVI User Manual Appendix 1
Page 74
T# Time (sec) Description Error Code Solution
18
22
25
27
20
24
26
HUD LED. This test measures the amount of electrical current
consumed by the red LED in the Head-Up Display (HUD),
when activated.
HUD Vibrator. This test measures the amount of electrical
current consumed by the vibrator motor in the Head-Up
Display (HUD), when activated.
Metabolic O
2
Solenoid #2. This test measures the amount of
electrical current consumed by the second metabolic solenoid
valve, when activated. It does not check that the solenoid
actually opens and closes (veried during the Positive Pressure
Loop Test, t49).
Diluent Calibration Solenoid. This test measures the amount of
electrical current consumed by the diluent calibration solenoid
valve, when activated. It does not check that the solenoid
actually opens and closes (veried during the Positive Pressure
Loop Test, t49).
Buddy-Light LED. This test measures the amount of electrical
current consumed by the red LED in the battery (Buddy-Light),
when activated.
Metabolic O2 Solenoid #1. This test measures the amount of
electrical current consumed by the rst metabolic solenoid
valve, when activated. It does not check that the solenoid
actually opens and closes (veried during the Positive Pressure
Loop Test, t49).
Oxygen Calibration Solenoid. This test measures the amount
of electrical current consumed by the oxygen calibration
solenoid valve, when activated. It does not check that the
solenoid actually opens and closes (veried during the Positive
Pressure Loop Test, t49).
4,5
4,5
9
9
4,5
9
9
11=Current
too low
12=Current
too high
11=Current
too low
12=Current
too high
11=Current
too low
12=Current
too high
11=Current
too low
12=Current
too high
11=Current
too low
12=Current
too high
11=Current
too low
12=Current
too high
11=Current
too low
12=Current
too high
1) Standard Response; 2) If test failure persists, or if no faint “click” sound
from the main electronics module can be heard at the start of this test, contact
an authorized Poseidon Service Center for repair.
1) Standard Response; 2) If test failure persists, or the HUD does not vibrate
during this test, contact an authorized Poseidon Service Center for repair.
1) Standard Response; 2) If test failure persists, or if no faint “click” sound
from the main electronics module can be heard at the start of this test, contact
an authorized Poseidon Service Center for repair.
1) Standard Response; 2) If test failure persists, or if no faint “click” sound
from the main electronics module can be heard at the start of this test,
contact an authorized Poseidon Service Center for repair.
1) Standard Response; 2) If test failure persists, or the Battery LED does not
turn on during this test, contact an authorized Poseidon Service Center for
repair.
1) Standard Response; 2) If test failure persists, or the HUD LED does not
turn on during this test, contact an authorized Poseidon Service Center for
repair.
1) Standard Response; 2) If test failure persists, or if no faint “click” sound
from the main electronics module can be heard at the start of this test, contact
an authorized Poseidon Service Center for repair.