Product Manual
SET UP (refer to figure 1 on page 4)
Safety Mesage! It is recommended that you install a pressure gauge on your pump to indicate a relative level of
pulling force.
1. Secure the threaded ram to bottom of puller post, then connect ram to air pump with hydraulic hose provided.
2. Slide the 9 feet pull chain thru the floating pully, idle pulley and power lever arm.
3. Secure the safety chain on floating pulley to an anchor pot or between two anchor pots using 6 feet claw hooks
chain
Note: The dual chain helps to devide the pull force exerted by the post and also allows positioning the post between
two anchor ports.
OPERATION
Note: The pull post is operated by a 10Ton 10 inch stroke hydraulic ram attains 20,000 pounds of pull on the chain
at 8950 psi pressure.
Safety Message! operate equipment from at least 6 feet from either side of post and chains.
1. Adjust the floating pulley to desire height to pull using the handle bar. For low pull, can pull without floating pulley,
just slide thru the idle pully.
2. Connect air nipple (not included) to air input port before connecting air hose.
3. Connect to suitable air supply, ensure air input pressure range from 95 to 175 psi.
4. Secure the pull chain before pulling object.
5. To operate, press the foot pedal of air pump until desire height or position is reached. Always monitor pressure
and load. Do not exceed 8950 psi and use caution when nearing this maximum operating ram pressure.
Caution! Never operate pump with release valve closed and disconnected from ram. If operated in this condition, the
hose and connections become pressurized. This increases burst hazard. Damage may occur to pump and its components
6. To release, simply press the release valve by stepping on the raised, stirrup shaped portion of the foot pedel.
7. Figure 2 below shows illustrations of common applications.
6
Figure 2 - Illustrations of different methods for pulling application