Porto-Power Blackhawk Automotive is a licensed trademark 2 Speed Hydraulic Hand Pump Operating Instructions & Parts Manual B65122 B65421 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 816-891-6390 sales@blackhawk-automotive.
ONE YEAR LIMITED WARRANTY For a period of one (1) year from date of purchase, SFA Companies will repair or replace, at its option, without charge, any of its products which fails due to a defect in material or workmanship under normal usage. This limited warranty is a consumer's exclusive remedy. Performance of any obligation under this warranty may be obtained by returning the warranted product, freight prepaid, to SFA Companies Warranty Service Department, 10939 N. Pomona Ave., Kansas City, MO 64153.
SAVE THESE INSTRUCTIONS For your safety read, understand, and follow the information contained within. The owner and operator shall have an understanding of this product and safe operating procedures before attempting to use this product. Make certain that the operator thoroughly understands the inherent dangers associated with the use and misuse of the product. If any doubt exists as to the safe and proper use of this product as outlined in this factory authorized manual, remove from service immediately.
SAFETY INSTRUCTIONS A BEFORE USE 1. Before using this product, read the operator's manual completely and familiarize yourself thoroughly with the product, its components and recognize the hazards associated with its use. Prepare the pump for use (see Figure 2). 2. Verify that the product and the application are compatible. Inspect before each use. Do not use if bent, broken, leaking or damaged components are noted. 3. Carefully remove the threaded plug in oil output port. 4.
ASSEMBLY Little, if any, assembly is required of this device. Always secure threaded connections with pipe thread compound. Tighten securely to prevent accidental removal of components while in use. Familiarize yourself with the specifications and illustrations in this owner's manual. Know your pump, its limitations and how it operates before attempting to use. Refer to Specification chart on page 3 for details of oil port thread size, usable oil capacity, and more. OPERATION 1.
TROUBLESHOOTING Symptom Application will not extend, move or respond to pressurized fluid Possible Causes • Overload condition • Release valve not closed Application responds to pressurized • Overload condition fluid, but system does not maintain • Release valve not closed pressure • Hydraulic unit malfunction • Malfunctioning coupler, damaged application Application will not return fluid to pump (i.e.
REPLACEMENT PARTS Available Parts: Please refer to the parts drawing when ordering parts. Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in the assembly sequence. When ordering parts, give model number, serial number and description below. Call or write for current pricing: SFA Companies. 10939 N. Pomona Ave. Kansas City, MO 64153, U.S.A. Tel:(816)891-6390 Fax:(816)891-6599 E-Mail: sales@blackhawk-automotive.